FabDigitFabDigit

Steel M42 Annealed vs M42 H&T 68-70 HRC

Steel · M42 temper comparison

M42 Annealed and M42 H&T 68-70 HRC are two conditions of the same steel grade, M42: Annealed versus H&T 68-70 HRC (maximum hardness). The chemistry is identical, so every difference below comes from the condition. M42 H&T 68-70 HRC is the stronger of the two: yield strength 1,800 MPa (261 ksi) against 620 MPa (89.9 ksi) for M42 Annealed, about 190% more; tensile strength follows at 1,900 MPa (276 ksi) vs 900 MPa (131 ksi). In exchange, M42 Annealed is the more ductile: elongation 12% versus 0% for M42 H&T 68-70 HRC, and M42 H&T 68-70 HRC is harder (69 HRC vs 25 HRC). M42 H&T 68-70 HRC runs hotter in service (560°C vs 400°C continuous) and M42 Annealed conducts electricity better (3.1 % IACS vs 2.6 % IACS). On the shop floor, M42 Annealed machines more easily (fair vs not recommended) and M42 Annealed welds better (poor vs not recommended).

M42 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

M42 H&T 68-70 HRCChoose it when strength drives the design, or when the part sees heat.

M42 Annealed vs M42 H&T 68-70 HRC: properties

M42 AnnealedM42 H&T 68-70 HRC

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

222 GPa32.2 Msi
224 GPa32.5 Msi

Tensile Strength (Ultimate)

900 MPa131 ksi
1,900 MPa276 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
1,800 MPa261 ksi

Elongation at Break

12%
0%

Reduction in Area

20%
0%

Compressive Strength

680 MPa98.6 ksi
3,800 MPa551 ksi

Shear Strength

545 MPa79 ksi
1,150 MPa167 ksi

Fatigue Strength (Endurance Limit)

400 MPa58 ksi
850 MPa123 ksi

Fracture Toughness (K_IC)

33 MPa·√m30 ksi·√in
12 MPa·√m10.9 ksi·√in

Charpy V-Notch Impact (RT)

9 J6.6 ft·lbf
2 J1.5 ft·lbf

Hardness, Rockwell C

25 HRC
69 HRC

Hardness, Vickers

270 HV
970 HV

Same in both: Shear Modulus 86 GPa12.5 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.28 · Hardness, Brinell 255 HB · Hardness, Rockwell B 101 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.98 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,290°C2,354 °F · Liquidus Temperature 1,420°C2,588 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

22 W/m·K12.7 BTU/hr·ft·°F
21 W/m·K12.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
560°C1,040 °F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

3.1 % IACS
2.6 % IACS

Electrical Resistivity

5.5×10⁻⁷ Ω·m21.7 µΩ·in
6.5×10⁻⁷ Ω·m25.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

18 / 100
20 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
3 / 100

Machinability Rating (AISI 1212 = 100 %)

42%
4%

Weldability

20 / 100
5 / 100

Formability (cold)

10 / 100
1 / 100

Same in both: Castability 20 / 100 · Brazeability / Solderability 55 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.4 kg CO₂/kg · Embodied Water 90 L/kg10.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleM42

M42 Annealed vs M42 H&T 68-70 HRC — frequently asked

Is M42 H&T 68-70 HRC stronger than M42 Annealed?

Yes. M42 H&T 68-70 HRC has a typical yield strength of 1,800 MPa (261 ksi) against 620 MPa (89.9 ksi) for M42 Annealed — about 190% more. Tensile strength is 1,900 MPa (276 ksi) vs 900 MPa (131 ksi).

Which condition does FabDigit quote by default, Annealed or H&T 68-70 HRC?

Annealed is the default M42 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, M42 Annealed or M42 H&T 68-70 HRC?

M42 Annealed. Its machinability rates fair (38/100) against not recommended (3/100) for M42 H&T 68-70 HRC; for welding the order is M42 Annealed first (poor, 20/100) then M42 H&T 68-70 HRC (not recommended, 5/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in M42 Annealed and M42 H&T 68-70 HRC side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.