FabDigitFabDigit

Steel HC260LA-CR vs HC260LA +ZF

Steel · HC260LA temper comparison

HC260LA-CR and HC260LA +ZF are two conditions of the same steel grade, HC260LA: CR (cold rolled) versus +ZF (galvannealed zinc-iron coating). The chemistry is identical, so every difference below comes from the condition. Both yield at about 295 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (cold rolled versus galvannealed zinc-iron coating). HC260LA-CR runs hotter in service (350°C vs 300°C continuous).

HC260LA-CRChoose it when the part sees heat.

HC260LA-CR vs HC260LA +ZF: properties

HC260LA-CRHC260LA +ZF

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

390 MPa56.6 ksi
385 MPa55.8 ksi

Yield Strength (0.2% offset)

295 MPa42.8 ksi
300 MPa43.5 ksi

Elongation at Break

30%
28%

Reduction in Area

60%
58%

Compressive Strength

295 MPa42.8 ksi
305 MPa44.2 ksi

Shear Strength

250 MPa36.3 ksi
248 MPa36 ksi

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
180 MPa26.1 ksi

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
36 J26.6 ft·lbf

Hardness, Brinell

115 HB
118 HB

Hardness, Rockwell B

70 HRB
71 HRB

Hardness, Vickers

122 HV
124 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3 · Fracture Toughness (K_IC) 100 MPa·√m91 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,500°C2,732 °F · Liquidus Temperature 1,530°C2,786 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
300°C572 °F

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

12 / 100
34 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
53 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
56%

Weldability

90 / 100
85 / 100

Formability (cold)

70 / 100
64 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.4 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleHC260LA

HC260LA-CR vs HC260LA +ZF — frequently asked

What is the difference between HC260LA-CR and HC260LA +ZF?

HC260LA-CR and HC260LA +ZF are two conditions of the same steel grade, HC260LA: CR (cold rolled) versus +ZF (galvannealed zinc-iron coating). The chemistry is identical, so every difference below comes from the condition. Both yield at about 295 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (cold rolled versus galvannealed zinc-iron coating).

Which condition does FabDigit quote by default, CR or +ZF?

CR is the default HC260LA condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, HC260LA-CR or HC260LA +ZF?

HC260LA-CR. Its weldability rates excellent (90/100) against excellent (85/100) for HC260LA +ZF.

Ready to make it?

Upload a CAD file and FabDigit prices the part in HC260LA-CR and HC260LA +ZF side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.