FabDigitFabDigit

Steel H26-HR vs H26-SR

Steel · H26 temper comparison

H26-HR and H26-SR are two conditions of the same steel grade, H26: HR (hot rolled) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. H26-HR is the stronger of the two: yield strength 760 MPa (110 ksi) against 575 MPa (83.4 ksi) for H26-SR, about 32% more; tensile strength follows at 1,100 MPa (160 ksi) vs 860 MPa (125 ksi). In exchange, H26-SR is the more ductile: elongation 17% versus 8% for H26-HR, and H26-HR is harder (330 HB vs 235 HB). On the shop floor, H26-SR machines more easily (30 vs 18 out of 100).

H26-HRChoose it when strength drives the design.

H26-SRChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

H26-HR vs H26-SR: properties

H26-HRH26-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,100 MPa160 ksi
860 MPa125 ksi

Yield Strength (0.2% offset)

760 MPa110 ksi
575 MPa83.4 ksi

Elongation at Break

8%
17%

Reduction in Area

20%
34%

Compressive Strength

1,150 MPa167 ksi
910 MPa132 ksi

Shear Strength

690 MPa100 ksi
545 MPa79 ksi

Charpy V-Notch Impact (RT)

11 J8.1 ft·lbf
24 J17.7 ft·lbf

Hardness, Brinell

330 HB
235 HB

Hardness, Rockwell B

98 HRB
99 HRB

Hardness, Vickers

345 HV
247 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 8.89 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,460°C2,660 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

25 W/m·K14.4 BTU/hr·ft·°F
26 W/m·K15 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.2 µm/m·K6.2 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 3.1 % IACS · Electrical Resistivity 5.5×10⁻⁷ Ω·m21.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 15 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

18 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
38%

Weldability

12 / 100
20 / 100

Formability (cold)

6 / 100
14 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 35 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 48 MJ/kg20,636 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 80 L/kg9.6 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleH26

H26-HR vs H26-SR — frequently asked

Is H26-HR stronger than H26-SR?

Yes. H26-HR has a typical yield strength of 760 MPa (110 ksi) against 575 MPa (83.4 ksi) for H26-SR — about 32% more. Tensile strength is 1,100 MPa (160 ksi) vs 860 MPa (125 ksi).

Which condition does FabDigit quote by default, HR or SR?

ANN is the default H26 condition in the FabDigit quote flow (neither HR nor SR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, H26-HR or H26-SR?

H26-SR, by a small margin. Both rate poor for machinability — 30/100 against 18/100 for H26-HR; for welding the order is H26-SR first (poor, 20/100) then H26-HR (not recommended, 12/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in H26-HR and H26-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.