FabDigitFabDigit

Steel H24 Annealed vs H24 Nitrided

Steel · H24 temper comparison

H24 Annealed and H24 Nitrided are two conditions of the same steel grade, H24: Annealed versus Nitrided. The chemistry is identical, so every difference below comes from the condition. H24 Nitrided is the stronger of the two: yield strength 1,450 MPa (210 ksi) against 500 MPa (72.5 ksi) for H24 Annealed, about 190% more; tensile strength follows at 1,720 MPa (249 ksi) vs 840 MPa (122 ksi). In exchange, H24 Annealed is the more ductile: elongation 18% versus 6% for H24 Nitrided, and H24 Nitrided is harder (480 HB vs 220 HB). H24 Nitrided runs hotter in service (600°C vs 550°C continuous). On the shop floor, H24 Annealed machines more easily (fair vs not recommended) and H24 Annealed welds better (poor vs not recommended).

H24 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

H24 NitridedChoose it when strength drives the design, or when the part sees heat.

H24 Annealed vs H24 Nitrided: properties

H24 AnnealedH24 Nitrided

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

840 MPa122 ksi
1,720 MPa249 ksi

Yield Strength (0.2% offset)

500 MPa72.5 ksi
1,450 MPa210 ksi

Elongation at Break

18%
6%

Reduction in Area

32%
14%

Compressive Strength

520 MPa75.4 ksi
2,000 MPa290 ksi

Shear Strength

540 MPa78.3 ksi
1,050 MPa152 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
830 MPa120 ksi

Charpy V-Notch Impact (RT)

22 J16.2 ft·lbf
7 J5.2 ft·lbf

Hardness, Brinell

220 HB
480 HB

Hardness, Vickers

232 HV
1,100 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Rockwell B 97 HRB

Physical

Density and transition temperatures.

Same in both: Density 8.55 g/cm³0.31 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

27 W/m·K15.6 BTU/hr·ft·°F
28 W/m·K16.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

550°C1,022 °F
600°C1,112 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11 µm/m·K6.1 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

3.1 % IACS
3 % IACS

Electrical Resistivity

5.5×10⁻⁷ Ω·m21.7 µΩ·in
5.7×10⁻⁷ Ω·m22.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

15 / 100
25 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.55 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
2 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
3%

Weldability

30 / 100
5 / 100

Formability (cold)

15 / 100
2 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 40 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 42 MJ/kg18,057 BTU/lb · Embodied Carbon (primary production) 3.4 kg CO₂/kg · Embodied Water 70 L/kg8.4 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleH24

H24 Annealed vs H24 Nitrided — frequently asked

Is H24 Nitrided stronger than H24 Annealed?

Yes. H24 Nitrided has a typical yield strength of 1,450 MPa (210 ksi) against 500 MPa (72.5 ksi) for H24 Annealed — about 190% more. Tensile strength is 1,720 MPa (249 ksi) vs 840 MPa (122 ksi).

Which condition does FabDigit quote by default, Annealed or Nitrided?

Annealed is the default H24 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, H24 Annealed or H24 Nitrided?

H24 Annealed. Its machinability rates fair (35/100) against not recommended (2/100) for H24 Nitrided; for welding the order is H24 Annealed first (poor, 30/100) then H24 Nitrided (not recommended, 5/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in H24 Annealed and H24 Nitrided side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.