FabDigitFabDigit

Steel GCr15SiMn-A vs GCr15SiMn-CD

Steel · GCr15SiMn temper comparison

GCr15SiMn-A and GCr15SiMn-CD are two conditions of the same steel grade, GCr15SiMn: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. GCr15SiMn-CD is the stronger of the two: yield strength 700 MPa (102 ksi) against 420 MPa (60.9 ksi) for GCr15SiMn-A, about 67% more; tensile strength follows at 880 MPa (128 ksi) vs 750 MPa (109 ksi). In exchange, GCr15SiMn-A is the more ductile: elongation 22% versus 10% for GCr15SiMn-CD, and GCr15SiMn-CD is harder (240 HB vs 195 HB). GCr15SiMn-A runs hotter in service (300°C vs 250°C continuous).

GCr15SiMn-AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

GCr15SiMn-CDChoose it when strength drives the design.

GCr15SiMn-A vs GCr15SiMn-CD: properties

GCr15SiMn-AGCr15SiMn-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

210 GPa30.5 Msi
208 GPa30.2 Msi

Tensile Strength (Ultimate)

750 MPa109 ksi
880 MPa128 ksi

Yield Strength (0.2% offset)

420 MPa60.9 ksi
700 MPa102 ksi

Elongation at Break

22%
10%

Reduction in Area

45%
35%

Compressive Strength

800 MPa116 ksi
950 MPa138 ksi

Shear Strength

450 MPa65.3 ksi
530 MPa76.9 ksi

Fatigue Strength (Endurance Limit)

360 MPa52.2 ksi
400 MPa58 ksi

Fracture Toughness (K_IC)

55 MPa·√m50.1 ksi·√in
45 MPa·√m41 ksi·√in

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

195 HB
240 HB

Hardness, Rockwell B

92 HRB
100 HRB

Hardness, Vickers

205 HV
252 HV

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.81 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
250°C482 °F

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.5 % IACS · Electrical Resistivity 2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
46 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
45%

Weldability

12 / 100
10 / 100

Formability (cold)

35 / 100
20 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 88 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 32 MJ/kg13,758 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleGCr15SiMn

GCr15SiMn-A vs GCr15SiMn-CD — frequently asked

Is GCr15SiMn-CD stronger than GCr15SiMn-A?

Yes. GCr15SiMn-CD has a typical yield strength of 700 MPa (102 ksi) against 420 MPa (60.9 ksi) for GCr15SiMn-A — about 67% more. Tensile strength is 880 MPa (128 ksi) vs 750 MPa (109 ksi).

Which condition does FabDigit quote by default, A or CD?

A is the default GCr15SiMn condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose GCr15SiMn-A over GCr15SiMn-CD?

Pick GCr15SiMn-A when the part is bent, formed or impact-loaded, or when the part sees heat. Pick GCr15SiMn-CD when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in GCr15SiMn-A and GCr15SiMn-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.