Steel G20CrNiMo-HR vs G20CrNiMo Q&T
Steel · G20CrNiMo temper comparison
G20CrNiMo-HR and G20CrNiMo Q&T are two conditions of the same steel grade, G20CrNiMo: HR (hot rolled) versus Q&T (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. G20CrNiMo Q&T is the stronger of the two: yield strength 850 MPa (123 ksi) against 450 MPa (65.3 ksi) for G20CrNiMo-HR, about 89% more; tensile strength follows at 1,080 MPa (157 ksi) vs 720 MPa (104 ksi). In exchange, G20CrNiMo-HR is the more ductile: elongation 22% versus 14% for G20CrNiMo Q&T, and G20CrNiMo Q&T is harder (320 HB vs 230 HB). G20CrNiMo-HR runs hotter in service (400°C vs 200°C continuous). On the shop floor, G20CrNiMo-HR machines more easily (50 vs 40 out of 100).
G20CrNiMo-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.
G20CrNiMo Q&TChoose it when strength drives the design.
G20CrNiMo-HR vs G20CrNiMo Q&T: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Shear Strength
Fatigue Strength (Endurance Limit)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell B
Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Fracture Toughness (K_IC) 85 MPa·√m77.4 ksi·√in
Physical
Density and transition temperatures.
Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F
Thermal
How each material carries heat and how hot it can run.
Max Service Temperature (continuous)
Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F
Electrical
Conductivity and insulation.
Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Formability (cold)
Same in both: Weldability 50 / 100 · Castability 30 / 100 · Brazeability / Solderability 60 / 100 · Polishability 80 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%
Strength versus weight
Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
G20CrNiMo-HR vs G20CrNiMo Q&T — frequently asked
Is G20CrNiMo Q&T stronger than G20CrNiMo-HR?
Yes. G20CrNiMo Q&T has a typical yield strength of 850 MPa (123 ksi) against 450 MPa (65.3 ksi) for G20CrNiMo-HR — about 89% more. Tensile strength is 1,080 MPa (157 ksi) vs 720 MPa (104 ksi).
Which condition does FabDigit quote by default, HR or Q&T?
A is the default G20CrNiMo condition in the FabDigit quote flow (neither HR nor Q&T). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, G20CrNiMo-HR or G20CrNiMo Q&T?
G20CrNiMo-HR, by a small margin. Both rate fair for machinability — 50/100 against 40/100 for G20CrNiMo Q&T.
Ready to make it?
Upload a CAD file and FabDigit prices the part in G20CrNiMo-HR and G20CrNiMo Q&T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.