FabDigitFabDigit

Steel F2-ANN vs F2 CD-ANN

Steel · F2 temper comparison

F2-ANN and F2 CD-ANN are two conditions of the same steel grade, F2: ANN (annealed) versus CD-ANN (cold Drawn Annealed). The chemistry is identical, so every difference below comes from the condition. F2 CD-ANN is the stronger of the two: yield strength 600 MPa (87 ksi) against 430 MPa (62.4 ksi) for F2-ANN, about 40% more; tensile strength follows at 830 MPa (120 ksi) vs 760 MPa (110 ksi). In exchange, F2-ANN is the more ductile: elongation 22% versus 12% for F2 CD-ANN, and F2 CD-ANN is harder (248 HB vs 223 HB).

F2-ANNChoose it when the part is bent, formed or impact-loaded.

F2 CD-ANNChoose it when strength drives the design.

F2-ANN vs F2 CD-ANN: properties

F2-ANNF2 CD-ANN

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

760 MPa110 ksi
830 MPa120 ksi

Yield Strength (0.2% offset)

430 MPa62.4 ksi
600 MPa87 ksi

Elongation at Break

22%
12%

Reduction in Area

45%
38%

Compressive Strength

450 MPa65.3 ksi
620 MPa89.9 ksi

Shear Strength

470 MPa68.2 ksi
510 MPa74 ksi

Fatigue Strength (Endurance Limit)

350 MPa50.8 ksi
375 MPa54.4 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

223 HB
248 HB

Hardness, Rockwell B

97 HRB
100 HRB

Hardness, Vickers

235 HV
260 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.75 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 30 W/m·K17.3 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.52 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
32%

Formability (cold)

30 / 100
20 / 100

Same in both: Weldability 12 / 100 · Brazeability / Solderability 40 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 36 MJ/kg15,477 BTU/lb · Embodied Carbon (primary production) 2.7 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleF2

F2-ANN vs F2 CD-ANN — frequently asked

Is F2 CD-ANN stronger than F2-ANN?

Yes. F2 CD-ANN has a typical yield strength of 600 MPa (87 ksi) against 430 MPa (62.4 ksi) for F2-ANN — about 40% more. Tensile strength is 830 MPa (120 ksi) vs 760 MPa (110 ksi).

Which condition does FabDigit quote by default, ANN or CD-ANN?

ANN is the default F2 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose F2-ANN over F2 CD-ANN?

Pick F2-ANN when the part is bent, formed or impact-loaded. Pick F2 CD-ANN when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in F2-ANN and F2 CD-ANN side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.