FabDigitFabDigit

Steel En40B-A vs En40B-N

Steel · En40B temper comparison

En40B-A and En40B-N are two conditions of the same steel grade, En40B: A (solution annealed) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. En40B-N is the stronger of the two: yield strength 540 MPa (78.3 ksi) against 450 MPa (65.3 ksi) for En40B-A, about 20% more; tensile strength follows at 800 MPa (116 ksi) vs 700 MPa (102 ksi). In exchange, En40B-A is the more ductile: elongation 20% versus 17% for En40B-N, and En40B-N is harder (245 HB vs 220 HB).

En40B-AChoose it when the part is bent, formed or impact-loaded.

En40B-NChoose it when strength drives the design.

En40B-A vs En40B-N: properties

En40B-AEn40B-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
800 MPa116 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
540 MPa78.3 ksi

Elongation at Break

20%
17%

Compressive Strength

750 MPa109 ksi
550 MPa79.8 ksi

Shear Strength

560 MPa81.2 ksi
480 MPa69.6 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
370 MPa53.7 ksi

Fracture Toughness (K_IC)

80 MPa·√m72.8 ksi·√in
90 MPa·√m81.9 ksi·√in

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

220 HB
245 HB

Hardness, Rockwell C

29 HRC
23 HRC

Hardness, Vickers

290 HV
257 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Reduction in Area 55%

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

34 W/m·K19.6 BTU/hr·ft·°F
35 W/m·K20.2 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 500°C932 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

6.6 % IACS
6.8 % IACS

Electrical Resistivity

2.6×10⁻⁷ Ω·m10.2 µΩ·in
2.55×10⁻⁷ Ω·m10 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 15 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
55%

Weldability

20 / 100
25 / 100

Formability (cold)

30 / 100
25 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 31 MJ/kg13,328 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleEn40B

En40B-A vs En40B-N — frequently asked

Is En40B-N stronger than En40B-A?

Yes. En40B-N has a typical yield strength of 540 MPa (78.3 ksi) against 450 MPa (65.3 ksi) for En40B-A — about 20% more. Tensile strength is 800 MPa (116 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, A or N?

T is the default En40B condition in the FabDigit quote flow (neither A nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, En40B-A or En40B-N?

En40B-A. Its machinability rates good (55/100) against fair (50/100) for En40B-N; for welding the order is En40B-N first (poor, 25/100) then En40B-A (poor, 20/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in En40B-A and En40B-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.