E90C-D2-AW and E90C-D2 PWHT are two conditions of the same steel grade, E90C-D2: AW (as-welded deposit) versus PWHT (post-weld heat treated). The chemistry is identical, so every difference below comes from the condition. E90C-D2-AW is the stronger of the two: yield strength 580 MPa (84.1 ksi) against 545 MPa (79 ksi) for E90C-D2 PWHT, about 6% more. In exchange, E90C-D2 PWHT is the more ductile: elongation 25% versus 22% for E90C-D2-AW, and E90C-D2-AW is harder (205 HB vs 190 HB).

E90C-D2-AWChoose it when strength drives the design.

E90C-D2 PWHTChoose it when the part is bent, formed or impact-loaded.

E90C-D2-AW vs E90C-D2 PWHT: properties

E90C-D2-AWE90C-D2 PWHT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

670 MPa97.2 ksi
640 MPa92.8 ksi

Yield Strength (0.2% offset)

580 MPa84.1 ksi
545 MPa79 ksi

Elongation at Break

22%
25%

Reduction in Area

55%
62%

Shear Strength

420 MPa60.9 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
275 MPa39.9 ksi

Charpy V-Notch Impact (RT)

70 J51.6 ft·lbf
85 J62.7 ft·lbf

Hardness, Brinell

205 HB
190 HB

Hardness, Rockwell B

94 HRB
91 HRB

Hardness, Vickers

215 HV
200 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,460°C2,660 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

42 W/m·K24.3 BTU/hr·ft·°F
43 W/m·K24.8 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
425°C797 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.8 % IACS
8 % IACS

Electrical Resistivity

2.2×10⁻⁷ Ω·m8.66 µΩ·in
2.15×10⁻⁷ Ω·m8.46 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 13 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
60%

Formability (cold)

40 / 100
45 / 100

Same in both: Weldability 90 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 33 MJ/kg14,187 BTU/lb · Embodied Carbon (primary production) 2.5 kg CO₂/kg · Embodied Water 65 L/kg7.8 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleE90C-D2

E90C-D2-AW vs E90C-D2 PWHT — frequently asked

Is E90C-D2-AW stronger than E90C-D2 PWHT?

Yes. E90C-D2-AW has a typical yield strength of 580 MPa (84.1 ksi) against 545 MPa (79 ksi) for E90C-D2 PWHT — about 6% more. Tensile strength is 670 MPa (97.2 ksi) vs 640 MPa (92.8 ksi).

Which condition does FabDigit quote by default, AW or PWHT?

AW is the default E90C-D2 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, E90C-D2-AW or E90C-D2 PWHT?

E90C-D2 PWHT. Its machinability rates good (55/100) against fair (50/100) for E90C-D2-AW.