FabDigitFabDigit

Steel E275K2 +C vs E275K2 +U

Steel · E275K2 temper comparison

E275K2 +C and E275K2 +U are two conditions of the same steel grade, E275K2: +C (cold drawn) versus +U (hot rolled). The chemistry is identical, so every difference below comes from the condition. E275K2 +C is the stronger of the two: yield strength 500 MPa (72.5 ksi) against 305 MPa (44.2 ksi) for E275K2 +U, about 64% more; tensile strength follows at 620 MPa (89.9 ksi) vs 500 MPa (72.5 ksi). In exchange, E275K2 +U is the more ductile: elongation 24% versus 10% for E275K2 +C, and E275K2 +C is harder (185 HB vs 150 HB).

E275K2 +CChoose it when strength drives the design.

E275K2 +UChoose it when the part is bent, formed or impact-loaded.

E275K2 +C vs E275K2 +U: properties

E275K2 +CE275K2 +U

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
500 MPa72.5 ksi

Yield Strength (0.2% offset)

500 MPa72.5 ksi
305 MPa44.2 ksi

Elongation at Break

10%
24%

Reduction in Area

40%
50%

Shear Strength

400 MPa58 ksi
330 MPa47.9 ksi

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
230 MPa33.4 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

185 HB
150 HB

Hardness, Rockwell B

91 HRB
80 HRB

Hardness, Vickers

195 HV
158 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 305 MPa44.2 ksi · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

72%
65%

Weldability

78 / 100
85 / 100

Formability (cold)

35 / 100
65 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleE275K2

E275K2 +C vs E275K2 +U — frequently asked

Is E275K2 +C stronger than E275K2 +U?

Yes. E275K2 +C has a typical yield strength of 500 MPa (72.5 ksi) against 305 MPa (44.2 ksi) for E275K2 +U — about 64% more. Tensile strength is 620 MPa (89.9 ksi) vs 500 MPa (72.5 ksi).

Which condition does FabDigit quote by default, +C or +U?

+U is the default E275K2 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, E275K2 +C or E275K2 +U?

E275K2 +C, by a small margin. Both rate good for machinability — 68/100 against 60/100 for E275K2 +U; for welding the order is E275K2 +U first (excellent, 85/100) then E275K2 +C (very good, 78/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in E275K2 +C and E275K2 +U side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.