E220 +A and E220 +SR are two conditions of the same steel grade, E220: +A (annealed) versus +SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. E220 +SR is the stronger of the two: yield strength 310 MPa (45 ksi) against 210 MPa (30.5 ksi) for E220 +A, about 48% more; tensile strength follows at 410 MPa (59.5 ksi) vs 330 MPa (47.9 ksi). In exchange, E220 +A is the more ductile: elongation 28% versus 14% for E220 +SR, and E220 +SR is harder (125 HB vs 100 HB). E220 +A runs hotter in service (350°C vs 300°C continuous).

E220 +AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

E220 +SRChoose it when strength drives the design.

E220 +A vs E220 +SR: properties

E220 +AE220 +SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

330 MPa47.9 ksi
410 MPa59.5 ksi

Yield Strength (0.2% offset)

210 MPa30.5 ksi
310 MPa45 ksi

Elongation at Break

28%
14%

Reduction in Area

55%
45%

Compressive Strength

250 MPa36.3 ksi
310 MPa45 ksi

Shear Strength

250 MPa36.3 ksi
285 MPa41.3 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
190 MPa27.6 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
95 MPa·√m86.5 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

100 HB
125 HB

Hardness, Rockwell B

55 HRB
70 HRB

Hardness, Vickers

118 HV
132 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
300°C572 °F

Same in both: Thermal Conductivity 51 W/m·K29.5 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.5 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

58%
70%

Weldability

96 / 100
92 / 100

Formability (cold)

92 / 100
68 / 100

Same in both: Brazeability / Solderability 75 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 24 MJ/kg10,318 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 30 L/kg3.6 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleE220

E220 +A vs E220 +SR — frequently asked

Is E220 +SR stronger than E220 +A?

Yes. E220 +SR has a typical yield strength of 310 MPa (45 ksi) against 210 MPa (30.5 ksi) for E220 +A — about 48% more. Tensile strength is 410 MPa (59.5 ksi) vs 330 MPa (47.9 ksi).

Which condition does FabDigit quote by default, +A or +SR?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

When should I choose E220 +A over E220 +SR?

Pick E220 +A when the part is bent, formed or impact-loaded, or when the part sees heat. Pick E220 +SR when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in E220 +A and E220 +SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.