FabDigitFabDigit

Steel E120C-K4-AW vs E120C-K4 PWHT

Steel · E120C-K4 temper comparison

E120C-K4-AW and E120C-K4 PWHT are two conditions of the same steel grade, E120C-K4: AW (as-welded deposit) versus PWHT (post-weld heat treated). The chemistry is identical, so every difference below comes from the condition. E120C-K4-AW is the stronger of the two: yield strength 800 MPa (116 ksi) against 730 MPa (106 ksi) for E120C-K4 PWHT, about 10% more; tensile strength follows at 880 MPa (128 ksi) vs 810 MPa (117 ksi). In exchange, E120C-K4 PWHT is the more ductile: elongation 19% versus 17% for E120C-K4-AW, and E120C-K4-AW is harder (270 HB vs 245 HB).

E120C-K4-AWChoose it when strength drives the design.

E120C-K4 PWHTChoose it when the part is bent, formed or impact-loaded.

E120C-K4-AW vs E120C-K4 PWHT: properties

E120C-K4-AWE120C-K4 PWHT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

880 MPa128 ksi
810 MPa117 ksi

Yield Strength (0.2% offset)

800 MPa116 ksi
730 MPa106 ksi

Elongation at Break

17%
19%

Reduction in Area

55%
60%

Shear Strength

530 MPa76.9 ksi
490 MPa71.1 ksi

Fatigue Strength (Endurance Limit)

370 MPa53.7 ksi
345 MPa50 ksi

Charpy V-Notch Impact (RT)

70 J51.6 ft·lbf
80 J59 ft·lbf

Hardness, Brinell

270 HB
245 HB

Hardness, Rockwell C

27 HRC
23 HRC

Hardness, Vickers

285 HV
257 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

40 W/m·K23.1 BTU/hr·ft·°F
41 W/m·K23.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
425°C797 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -51°C-60 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

2.4×10⁻⁷ Ω·m9.45 µΩ·in
2.35×10⁻⁷ Ω·m9.25 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 14 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
48%

Formability (cold)

25 / 100
30 / 100

Same in both: Weldability 80 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 32 MJ/kg13,758 BTU/lb · Embodied Carbon (primary production) 2.5 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleE120C-K4

E120C-K4-AW vs E120C-K4 PWHT — frequently asked

Is E120C-K4-AW stronger than E120C-K4 PWHT?

Yes. E120C-K4-AW has a typical yield strength of 800 MPa (116 ksi) against 730 MPa (106 ksi) for E120C-K4 PWHT — about 10% more. Tensile strength is 880 MPa (128 ksi) vs 810 MPa (117 ksi).

Which condition does FabDigit quote by default, AW or PWHT?

AW is the default E120C-K4 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, E120C-K4-AW or E120C-K4 PWHT?

E120C-K4 PWHT, by a small margin. Both rate fair for machinability — 42/100 against 35/100 for E120C-K4-AW.

Ready to make it?

Upload a CAD file and FabDigit prices the part in E120C-K4-AW and E120C-K4 PWHT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.