FabDigitFabDigit

Steel Ductile Iron As Cast vs Ductile Iron Q&T

Steel · Ductile Iron temper comparison

Ductile Iron As Cast and Ductile Iron Q&T are two conditions of the same steel grade, Ductile Iron: As Cast versus Q&T (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. Ductile Iron Q&T is the stronger of the two: yield strength 700 MPa (102 ksi) against 340 MPa (49.3 ksi) for Ductile Iron As Cast, about 106% more; tensile strength follows at 900 MPa (131 ksi) vs 480 MPa (69.6 ksi). In exchange, Ductile Iron As Cast is the more ductile: elongation 14% versus 3% for Ductile Iron Q&T, and Ductile Iron Q&T is harder (320 HB vs 187 HB). Ductile Iron As Cast runs hotter in service (400°C vs 300°C continuous) and Ductile Iron As Cast conducts heat better (33 W/m·K vs 26 W/m·K). On the shop floor, Ductile Iron As Cast machines more easily (good vs fair) and Ductile Iron As Cast welds better (fair vs poor).

Ductile Iron As CastChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Ductile Iron Q&TChoose it when strength drives the design.

Ductile Iron As Cast vs Ductile Iron Q&T: properties

Ductile Iron As CastDuctile Iron Q&T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

480 MPa69.6 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

340 MPa49.3 ksi
700 MPa102 ksi

Elongation at Break

14%
3%

Shear Strength

430 MPa62.4 ksi
780 MPa113 ksi

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
340 MPa49.3 ksi

Fracture Toughness (K_IC)

42 MPa·√m38.2 ksi·√in
32 MPa·√m29.1 ksi·√in

Charpy V-Notch Impact (RT)

10 J7.4 ft·lbf
4 J3 ft·lbf

Hardness, Brinell

187 HB
320 HB

Same in both: Elastic (Young's) Modulus 169 GPa24.5 Msi · Shear Modulus 65 GPa9.4 Msi · Bulk Modulus 130 GPa18.9 Msi · Poisson's Ratio 0.28 · Reduction in Area 12% · Compressive Strength 700 MPa102 ksi · Hardness, Rockwell B 90 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.1 g/cm³0.26 lb/in³ · Melting Point (Solidus) 1,150°C2,102 °F · Liquidus Temperature 1,175°C2,147 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

33 W/m·K19.1 BTU/hr·ft·°F
26 W/m·K15 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
300°C572 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 220 J/g94.6 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 3.1 % IACS · Electrical Resistivity 5.6×10⁻⁷ Ω·m22 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 16 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
35%

Weldability

35 / 100
15 / 100

Same in both: Formability (cold) 8 / 100 · Castability 88 / 100 · Brazeability / Solderability 40 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 21 MJ/kg9,028 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleDuctile Iron

Ductile Iron As Cast vs Ductile Iron Q&T — frequently asked

Is Ductile Iron Q&T stronger than Ductile Iron As Cast?

Yes. Ductile Iron Q&T has a typical yield strength of 700 MPa (102 ksi) against 340 MPa (49.3 ksi) for Ductile Iron As Cast — about 106% more. Tensile strength is 900 MPa (131 ksi) vs 480 MPa (69.6 ksi).

Which condition does FabDigit quote by default, As Cast or Q&T?

As Cast is the default Ductile Iron condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Ductile Iron As Cast or Ductile Iron Q&T?

Ductile Iron As Cast. Its machinability rates good (68/100) against fair (38/100) for Ductile Iron Q&T; for welding the order is Ductile Iron As Cast first (fair, 35/100) then Ductile Iron Q&T (poor, 15/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Ductile Iron As Cast and Ductile Iron Q&T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.