FabDigitFabDigit

Steel C8C +U vs C8C +U+C

Steel · C8C temper comparison

C8C +U and C8C +U+C are two conditions of the same steel grade, C8C: +U (hot rolled) versus +U+C (cold drawn from untreated (as-rolled) condition). The chemistry is identical, so every difference below comes from the condition. C8C +U+C is the stronger of the two: yield strength 385 MPa (55.8 ksi) against 215 MPa (31.2 ksi) for C8C +U, about 79% more; tensile strength follows at 460 MPa (66.7 ksi) vs 340 MPa (49.3 ksi). In exchange, C8C +U is the more ductile: elongation 32% versus 11% for C8C +U+C, and C8C +U+C is harder (135 HB vs 100 HB). C8C +U runs hotter in service (400°C vs 300°C continuous).

C8C +UChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C8C +U+CChoose it when strength drives the design.

C8C +U vs C8C +U+C: properties

C8C +UC8C +U+C

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

340 MPa49.3 ksi
460 MPa66.7 ksi

Yield Strength (0.2% offset)

215 MPa31.2 ksi
385 MPa55.8 ksi

Elongation at Break

32%
11%

Reduction in Area

68%
62%

Shear Strength

225 MPa32.6 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

165 MPa23.9 ksi
215 MPa31.2 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

100 HB
135 HB

Hardness, Rockwell B

55 HRB
74 HRB

Hardness, Vickers

105 HV
140 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 390 MPa56.6 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,525°C2,777 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
300°C572 °F

Same in both: Thermal Conductivity 51 W/m·K29.5 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 11 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
55%

Weldability

96 / 100
95 / 100

Formability (cold)

95 / 100
82 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 75 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 27 MJ/kg11,608 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleC8C

C8C +U vs C8C +U+C — frequently asked

Is C8C +U+C stronger than C8C +U?

Yes. C8C +U+C has a typical yield strength of 385 MPa (55.8 ksi) against 215 MPa (31.2 ksi) for C8C +U — about 79% more. Tensile strength is 460 MPa (66.7 ksi) vs 340 MPa (49.3 ksi).

Which condition does FabDigit quote by default, +U or +U+C?

+U+C is the default C8C condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C8C +U or C8C +U+C?

C8C +U+C, by a small margin. Both rate fair for machinability — 45/100 against 38/100 for C8C +U.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C8C +U and C8C +U+C side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.