FabDigitFabDigit

Steel C55 +AR vs C55 +C

Steel · C55 temper comparison

C55 +AR and C55 +C are two conditions of the same steel grade, C55: +AR (hot rolled) versus +C (cold drawn). The chemistry is identical, so every difference below comes from the condition. C55 +C is the stronger of the two: yield strength 650 MPa (94.3 ksi) against 420 MPa (60.9 ksi) for C55 +AR, about 55% more; tensile strength follows at 830 MPa (120 ksi) vs 780 MPa (113 ksi). In exchange, C55 +AR is the more ductile: elongation 14% versus 9% for C55 +C, and C55 +C is harder (250 HB vs 225 HB).

C55 +ARChoose it when the part is bent, formed or impact-loaded.

C55 +CChoose it when strength drives the design.

C55 +AR vs C55 +C: properties

C55 +ARC55 +C

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

780 MPa113 ksi
830 MPa120 ksi

Yield Strength (0.2% offset)

420 MPa60.9 ksi
650 MPa94.3 ksi

Elongation at Break

14%
9%

Reduction in Area

35%
30%

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
360 MPa52.2 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

225 HB
250 HB

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 420 MPa60.9 ksi · Shear Strength 490 MPa71.1 ksi · Fracture Toughness (K_IC) 55 MPa·√m50.1 ksi·√in · Hardness, Rockwell B 96 HRB · Hardness, Vickers 230 HV

Physical

Density and transition temperatures.

Same in both: Density 7.84 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 47 W/m·K27.2 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.4 µm/m·K6.3 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8.6 % IACS · Electrical Resistivity 2×10⁻⁷ Ω·m7.87 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
60%

Formability (cold)

28 / 100
20 / 100

Same in both: Weldability 30 / 100 · Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleC55

C55 +AR vs C55 +C — frequently asked

Is C55 +C stronger than C55 +AR?

Yes. C55 +C has a typical yield strength of 650 MPa (94.3 ksi) against 420 MPa (60.9 ksi) for C55 +AR — about 55% more. Tensile strength is 830 MPa (120 ksi) vs 780 MPa (113 ksi).

Which condition does FabDigit quote by default, +AR or +C?

+N is the default C55 condition in the FabDigit quote flow (neither +AR nor +C). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C55 +AR or C55 +C?

C55 +C, by a small margin. Both rate fair for machinability — 50/100 against 42/100 for C55 +AR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C55 +AR and C55 +C side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.