FabDigitFabDigit

Steel C50-N vs C50-QT

Steel · C50 temper comparison

C50-N and C50-QT are two conditions of the same steel grade, C50: N (normalized) versus QT (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. C50-QT is the stronger of the two: yield strength 580 MPa (84.1 ksi) against 425 MPa (61.6 ksi) for C50-N, about 36% more; tensile strength follows at 870 MPa (126 ksi) vs 750 MPa (109 ksi). In exchange, C50-N is the more ductile: elongation 20% versus 15% for C50-QT, and C50-QT is harder (260 HB vs 217 HB).

C50-NChoose it when the part is bent, formed or impact-loaded.

C50-QTChoose it when strength drives the design.

C50-N vs C50-QT: properties

C50-NC50-QT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

750 MPa109 ksi
870 MPa126 ksi

Yield Strength (0.2% offset)

425 MPa61.6 ksi
580 MPa84.1 ksi

Elongation at Break

20%
15%

Reduction in Area

39%
45%

Fatigue Strength (Endurance Limit)

350 MPa50.8 ksi
400 MPa58 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

217 HB
260 HB

Hardness, Vickers

228 HV
273 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 430 MPa62.4 ksi · Shear Strength 450 MPa65.3 ksi · Fracture Toughness (K_IC) 55 MPa·√m50.1 ksi·√in · Hardness, Rockwell B 96 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.5 % IACS · Electrical Resistivity 1.65×10⁻⁷ Ω·m6.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
47 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
45%

Same in both: Weldability 32 / 100 · Formability (cold) 32 / 100 · Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleC50

C50-N vs C50-QT — frequently asked

Is C50-QT stronger than C50-N?

Yes. C50-QT has a typical yield strength of 580 MPa (84.1 ksi) against 425 MPa (61.6 ksi) for C50-N — about 36% more. Tensile strength is 870 MPa (126 ksi) vs 750 MPa (109 ksi).

Which condition does FabDigit quote by default, N or QT?

N is the default C50 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C50-N or C50-QT?

C50-N, by a small margin. Both rate fair for machinability — 52/100 against 47/100 for C50-QT.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C50-N and C50-QT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.