FabDigitFabDigit

Steel C15R +A vs C15R +C

Steel · C15R temper comparison

C15R +A and C15R +C are two conditions of the same steel grade, C15R: +A (annealed) versus +C (cold drawn). The chemistry is identical, so every difference below comes from the condition. C15R +C is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 250 MPa (36.3 ksi) for C15R +A, about 80% more; tensile strength follows at 560 MPa (81.2 ksi) vs 420 MPa (60.9 ksi). In exchange, C15R +A is the more ductile: elongation 30% versus 12% for C15R +C, and C15R +C is harder (165 HB vs 125 HB). On the shop floor, C15R +C machines more easily (good vs fair).

C15R +AChoose it when the part is bent, formed or impact-loaded.

C15R +CChoose it when strength drives the design, or when the part is machined in volume.

C15R +A vs C15R +C: properties

C15R +AC15R +C

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

420 MPa60.9 ksi
560 MPa81.2 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
450 MPa65.3 ksi

Elongation at Break

30%
12%

Reduction in Area

60%
45%

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
245 MPa35.5 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

125 HB
165 HB

Hardness, Rockwell B

70 HRB
85 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 250 MPa36.3 ksi · Shear Strength 270 MPa39.2 ksi · Fracture Toughness (K_IC) 110 MPa·√m100 ksi·√in · Hardness, Vickers 130 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,460°C2,660 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.8 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.5 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
65 / 100

Machinability Rating (AISI 1212 = 100 %)

58%
70%

Formability (cold)

90 / 100
60 / 100

Same in both: Weldability 92 / 100 · Brazeability / Solderability 80 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleC15R

C15R +A vs C15R +C — frequently asked

Is C15R +C stronger than C15R +A?

Yes. C15R +C has a typical yield strength of 450 MPa (65.3 ksi) against 250 MPa (36.3 ksi) for C15R +A — about 80% more. Tensile strength is 560 MPa (81.2 ksi) vs 420 MPa (60.9 ksi).

Which condition does FabDigit quote by default, +A or +C?

+A is the default C15R condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C15R +A or C15R +C?

C15R +C. Its machinability rates good (65/100) against fair (52/100) for C15R +A.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C15R +A and C15R +C side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.