C15C +A and C15C +U+C are two conditions of the same steel grade, C15C: +A (annealed) versus +U+C (untreated then cold drawn). The chemistry is identical, so every difference below comes from the condition. C15C +U+C is the stronger of the two: yield strength 460 MPa (66.7 ksi) against 240 MPa (34.8 ksi) for C15C +A, about 92% more; tensile strength follows at 540 MPa (78.3 ksi) vs 400 MPa (58 ksi). In exchange, C15C +A is the more ductile: elongation 31% versus 10% for C15C +U+C, and C15C +U+C is harder (160 HB vs 115 HB). C15C +A runs hotter in service (350°C vs 300°C continuous). On the shop floor, C15C +U+C machines more easily (good vs fair).

C15C +AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C15C +U+CChoose it when strength drives the design, or when the part is machined in volume.

C15C +A vs C15C +U+C: properties

C15C +AC15C +U+C

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
540 MPa78.3 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
460 MPa66.7 ksi

Elongation at Break

31%
10%

Reduction in Area

65%
52%

Compressive Strength

240 MPa34.8 ksi
360 MPa52.2 ksi

Shear Strength

255 MPa37 ksi
340 MPa49.3 ksi

Fatigue Strength (Endurance Limit)

195 MPa28.3 ksi
250 MPa36.3 ksi

Fracture Toughness (K_IC)

140 MPa·√m127 ksi·√in
120 MPa·√m109 ksi·√in

Charpy V-Notch Impact (RT)

95 J70.1 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

115 HB
160 HB

Hardness, Rockwell B

65 HRB
83 HRB

Hardness, Vickers

120 HV
168 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,465°C2,669 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

52 W/m·K30 BTU/hr·ft·°F
51 W/m·K29.5 BTU/hr·ft·°F

Max Service Temperature (continuous)

350°C662 °F
300°C572 °F

Same in both: Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.8 % IACS
10.5 % IACS

Electrical Resistivity

1.6×10⁻⁷ Ω·m6.3 µΩ·in
1.65×10⁻⁷ Ω·m6.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
70%

Weldability

93 / 100
92 / 100

Formability (cold)

92 / 100
62 / 100

Same in both: Brazeability / Solderability 75 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleC15C

C15C +A vs C15C +U+C — frequently asked

Is C15C +U+C stronger than C15C +A?

Yes. C15C +U+C has a typical yield strength of 460 MPa (66.7 ksi) against 240 MPa (34.8 ksi) for C15C +A — about 92% more. Tensile strength is 540 MPa (78.3 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, +A or +U+C?

+AC+C is the default C15C condition in the FabDigit quote flow (neither +A nor +U+C). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C15C +A or C15C +U+C?

C15C +U+C. Its machinability rates good (62/100) against fair (50/100) for C15C +A.