FabDigitFabDigit

Steel A653-CR vs A653-SS37

Steel · A653 temper comparison

A653-CR and A653-SS37 are two conditions of the same steel grade, A653: CR (cold rolled) versus SS37 (SS Grade 37 [255]). The chemistry is identical, so every difference below comes from the condition. A653-SS37 is the stronger of the two: yield strength 285 MPa (41.3 ksi) against 230 MPa (33.4 ksi) for A653-CR, about 24% more; tensile strength follows at 380 MPa (55.1 ksi) vs 330 MPa (47.9 ksi). In exchange, A653-CR is the more ductile: elongation 38% versus 24% for A653-SS37, and A653-SS37 is harder (112 HB vs 100 HB).

A653-CRChoose it when the part is bent, formed or impact-loaded.

A653-SS37Choose it when strength drives the design.

A653-CR vs A653-SS37: properties

A653-CRA653-SS37

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

330 MPa47.9 ksi
380 MPa55.1 ksi

Yield Strength (0.2% offset)

230 MPa33.4 ksi
285 MPa41.3 ksi

Elongation at Break

38%
24%

Reduction in Area

62%
58%

Compressive Strength

230 MPa33.4 ksi
285 MPa41.3 ksi

Shear Strength

215 MPa31.2 ksi
250 MPa36.3 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
172 MPa24.9 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

100 HB
112 HB

Hardness, Rockwell B

55 HRB
65 HRB

Hardness, Vickers

105 HV
118 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

52 W/m·K30 BTU/hr·ft·°F
51 W/m·K29.5 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1.6×10⁻⁷ Ω·m6.3 µΩ·in
1.62×10⁻⁷ Ω·m6.38 µΩ·in

Same in both: Electrical Conductivity 10.5 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

40 / 100
38 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -1.02 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
68%

Weldability

78 / 100
74 / 100

Formability (cold)

92 / 100
74 / 100

Polishability

45 / 100
25 / 100

Same in both: Brazeability / Solderability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.5 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA653

A653-CR vs A653-SS37 — frequently asked

Is A653-SS37 stronger than A653-CR?

Yes. A653-SS37 has a typical yield strength of 285 MPa (41.3 ksi) against 230 MPa (33.4 ksi) for A653-CR — about 24% more. Tensile strength is 380 MPa (55.1 ksi) vs 330 MPa (47.9 ksi).

Which condition does FabDigit quote by default, CR or SS37?

HR is the default A653 condition in the FabDigit quote flow (neither CR nor SS37). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose A653-CR over A653-SS37?

Pick A653-CR when the part is bent, formed or impact-loaded. Pick A653-SS37 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A653-CR and A653-SS37 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.