FabDigitFabDigit

Steel A369 Grade FPA-ANN vs A369 Grade FPA-N

Steel · A369 Grade FPA temper comparison

A369 Grade FPA-ANN and A369 Grade FPA-N are two conditions of the same steel grade, A369 Grade FPA: ANN (annealed) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. A369 Grade FPA-N is the stronger of the two: yield strength 265 MPa (38.4 ksi) against 230 MPa (33.4 ksi) for A369 Grade FPA-ANN, about 15% more; tensile strength follows at 430 MPa (62.4 ksi) vs 390 MPa (56.6 ksi). In exchange, A369 Grade FPA-ANN is the more ductile: elongation 38% versus 33% for A369 Grade FPA-N, and A369 Grade FPA-N is harder (130 HB vs 112 HB).

A369 Grade FPA-ANNChoose it when the part is bent, formed or impact-loaded.

A369 Grade FPA-NChoose it when strength drives the design.

A369 Grade FPA-ANN vs A369 Grade FPA-N: properties

A369 Grade FPA-ANNA369 Grade FPA-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

390 MPa56.6 ksi
430 MPa62.4 ksi

Yield Strength (0.2% offset)

230 MPa33.4 ksi
265 MPa38.4 ksi

Elongation at Break

38%
33%

Reduction in Area

62%
55%

Compressive Strength

250 MPa36.3 ksi
265 MPa38.4 ksi

Shear Strength

270 MPa39.2 ksi
280 MPa40.6 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
195 MPa28.3 ksi

Fracture Toughness (K_IC)

130 MPa·√m118 ksi·√in
125 MPa·√m114 ksi·√in

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
85 J62.7 ft·lbf

Hardness, Brinell

112 HB
130 HB

Hardness, Rockwell B

63 HRB
72 HRB

Hardness, Vickers

126 HV
137 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

52 W/m·K30 BTU/hr·ft·°F
51 W/m·K29.5 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 425°C797 °F · Min Service Temperature -29°C-20 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

70%
65%

Formability (cold)

82 / 100
72 / 100

Same in both: Machinability 65 / 100 · Weldability 92 / 100 · Castability 55 / 100 · Brazeability / Solderability 70 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA369 Grade FPA

A369 Grade FPA-ANN vs A369 Grade FPA-N — frequently asked

Is A369 Grade FPA-N stronger than A369 Grade FPA-ANN?

Yes. A369 Grade FPA-N has a typical yield strength of 265 MPa (38.4 ksi) against 230 MPa (33.4 ksi) for A369 Grade FPA-ANN — about 15% more. Tensile strength is 430 MPa (62.4 ksi) vs 390 MPa (56.6 ksi).

Which condition does FabDigit quote by default, ANN or N?

N+T is the default A369 Grade FPA condition in the FabDigit quote flow (neither ANN nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose A369 Grade FPA-ANN over A369 Grade FPA-N?

Pick A369 Grade FPA-ANN when the part is bent, formed or impact-loaded. Pick A369 Grade FPA-N when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A369 Grade FPA-ANN and A369 Grade FPA-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.