FabDigitFabDigit

Steel A369 FP5 Annealed vs A369 FP5 N+T

Steel · A369 FP5 temper comparison

A369 FP5 Annealed and A369 FP5 N+T are two conditions of the same steel grade, A369 FP5: Annealed versus N+T (normalized and tempered). The chemistry is identical, so every difference below comes from the condition. A369 FP5 N+T is the stronger of the two: yield strength 400 MPa (58 ksi) against 305 MPa (44.2 ksi) for A369 FP5 Annealed, about 31% more; tensile strength follows at 585 MPa (84.8 ksi) vs 500 MPa (72.5 ksi). In exchange, A369 FP5 Annealed is the more ductile: elongation 30% versus 24% for A369 FP5 N+T, and A369 FP5 N+T is harder (175 HB vs 150 HB).

A369 FP5 AnnealedChoose it when the part is bent, formed or impact-loaded.

A369 FP5 N+TChoose it when strength drives the design.

A369 FP5 Annealed vs A369 FP5 N+T: properties

A369 FP5 AnnealedA369 FP5 N+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

500 MPa72.5 ksi
585 MPa84.8 ksi

Yield Strength (0.2% offset)

305 MPa44.2 ksi
400 MPa58 ksi

Elongation at Break

30%
24%

Reduction in Area

62%
58%

Fatigue Strength (Endurance Limit)

235 MPa34.1 ksi
275 MPa39.9 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
130 MPa·√m118 ksi·√in

Charpy V-Notch Impact (RT)

65 J47.9 ft·lbf
80 J59 ft·lbf

Hardness, Brinell

150 HB
175 HB

Hardness, Rockwell B

80 HRB
88 HRB

Same in both: Elastic (Young's) Modulus 213 GPa30.9 Msi · Shear Modulus 82 GPa11.9 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 310 MPa45 ksi · Shear Strength 330 MPa47.9 ksi · Hardness, Vickers 163 HV

Physical

Density and transition temperatures.

Same in both: Density 7.78 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,450°C2,642 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

620°C1,148 °F
640°C1,184 °F

Same in both: Thermal Conductivity 36 W/m·K20.8 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -29°C-20 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.9 % IACS · Electrical Resistivity 6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.58 V · Corrosion Resistance 30 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
44 / 100

Machinability Rating (AISI 1212 = 100 %)

58%
48%

Formability (cold)

50 / 100
38 / 100

Same in both: Weldability 45 / 100 · Brazeability / Solderability 45 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 32 MJ/kg13,758 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA369 FP5

A369 FP5 Annealed vs A369 FP5 N+T — frequently asked

Is A369 FP5 N+T stronger than A369 FP5 Annealed?

Yes. A369 FP5 N+T has a typical yield strength of 400 MPa (58 ksi) against 305 MPa (44.2 ksi) for A369 FP5 Annealed — about 31% more. Tensile strength is 585 MPa (84.8 ksi) vs 500 MPa (72.5 ksi).

Which condition does FabDigit quote by default, Annealed or N+T?

Annealed is the default A369 FP5 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, A369 FP5 Annealed or A369 FP5 N+T?

A369 FP5 Annealed, by a small margin. Both rate fair for machinability — 52/100 against 44/100 for A369 FP5 N+T.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A369 FP5 Annealed and A369 FP5 N+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.