FabDigitFabDigit

Steel A228-CD vs A228 CD-FINE

Steel · A228 temper comparison

A228-CD and A228 CD-FINE are two conditions of the same steel grade, A228: CD (cold drawn) versus CD-FINE. The chemistry is identical, so every difference below comes from the condition. A228 CD-FINE is the stronger of the two: yield strength 2,400 MPa (348 ksi) against 1,950 MPa (283 ksi) for A228-CD, about 23% more; tensile strength follows at 2,800 MPa (406 ksi) vs 2,300 MPa (334 ksi). In exchange, A228-CD is the more ductile: elongation 3% versus 2% for A228 CD-FINE, and A228 CD-FINE is harder (57 HRC vs 52 HRC). A228-CD runs hotter in service (120°C vs 100°C continuous).

A228-CDChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

A228 CD-FINEChoose it when strength drives the design.

A228-CD vs A228 CD-FINE: properties

A228-CDA228 CD-FINE

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

2,300 MPa334 ksi
2,800 MPa406 ksi

Yield Strength (0.2% offset)

1,950 MPa283 ksi
2,400 MPa348 ksi

Elongation at Break

3%
2%

Reduction in Area

40%
35%

Compressive Strength

1,900 MPa276 ksi
2,300 MPa334 ksi

Shear Strength

1,440 MPa209 ksi
1,750 MPa254 ksi

Fatigue Strength (Endurance Limit)

730 MPa106 ksi
850 MPa123 ksi

Hardness, Rockwell C

52 HRC
57 HRC

Hardness, Vickers

610 HV
700 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 79.3 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Brinell 530 HB

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

46 W/m·K26.6 BTU/hr·ft·°F
45 W/m·K26 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
100°C212 °F

Same in both: Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.5 µm/m·K6.9 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8.6 % IACS
8.3 % IACS

Electrical Resistivity

2×10⁻⁷ Ω·m7.87 µΩ·in
2.08×10⁻⁷ Ω·m8.19 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

16 / 100
15 / 100

Machinability Rating (AISI 1212 = 100 %)

18%
15%

Weldability

10 / 100
8 / 100

Formability (cold)

30 / 100
25 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 27 MJ/kg11,608 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA228

A228-CD vs A228 CD-FINE — frequently asked

Is A228 CD-FINE stronger than A228-CD?

Yes. A228 CD-FINE has a typical yield strength of 2,400 MPa (348 ksi) against 1,950 MPa (283 ksi) for A228-CD — about 23% more. Tensile strength is 2,800 MPa (406 ksi) vs 2,300 MPa (334 ksi).

Which condition does FabDigit quote by default, CD or CD-FINE?

CD is the default A228 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose A228-CD over A228 CD-FINE?

Pick A228-CD when the part is bent, formed or impact-loaded, or when the part sees heat. Pick A228 CD-FINE when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A228-CD and A228 CD-FINE side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.