FabDigitFabDigit

Steel A2 Annealed vs A2 HT 57-59 HRC

Steel · A2 temper comparison

A2 Annealed and A2 HT 57-59 HRC are two conditions of the same steel grade, A2: Annealed versus HT 57-59 HRC (hardened & Tempered 57–59 HRC). The chemistry is identical, so every difference below comes from the condition. A2 HT 57-59 HRC is the stronger of the two: yield strength 1,800 MPa (261 ksi) against 470 MPa (68.2 ksi) for A2 Annealed, about 3.8 times as much; tensile strength follows at 2,050 MPa (297 ksi) vs 740 MPa (107 ksi). In exchange, A2 Annealed is the more ductile: elongation 22% versus 2% for A2 HT 57-59 HRC, and A2 HT 57-59 HRC is harder (650 HV vs 230 HV). A2 Annealed runs hotter in service (425°C vs 250°C continuous). On the shop floor, A2 Annealed machines more easily (fair vs not recommended) and A2 Annealed welds better (poor vs not recommended).

A2 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

A2 HT 57-59 HRCChoose it when strength drives the design.

A2 Annealed vs A2 HT 57-59 HRC: properties

A2 AnnealedA2 HT 57-59 HRC

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

203 GPa29.4 Msi
208 GPa30.2 Msi

Tensile Strength (Ultimate)

740 MPa107 ksi
2,050 MPa297 ksi

Yield Strength (0.2% offset)

470 MPa68.2 ksi
1,800 MPa261 ksi

Elongation at Break

22%
2%

Reduction in Area

45%
4%

Compressive Strength

500 MPa72.5 ksi
2,200 MPa319 ksi

Shear Strength

450 MPa65.3 ksi
1,250 MPa181 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
730 MPa106 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
11 J8.1 ft·lbf

Hardness, Vickers

230 HV
650 HV

Same in both: Shear Modulus 78 GPa11.3 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28 · Hardness, Brinell 217 HB · Hardness, Rockwell B 96 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.86 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,465°C2,669 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

26 W/m·K15 BTU/hr·ft·°F
24.5 W/m·K14.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

425°C797 °F
250°C482 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.7 µm/m·K5.9 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.7 % IACS
2.5 % IACS

Electrical Resistivity

6.5×10⁻⁷ Ω·m25.6 µΩ·in
6.9×10⁻⁷ Ω·m27.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

20 / 100
19 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
12 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
10%

Weldability

20 / 100
7 / 100

Formability (cold)

35 / 100
4 / 100

Same in both: Castability 20 / 100 · Brazeability / Solderability 40 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 36 MJ/kg15,477 BTU/lb · Embodied Carbon (primary production) 2.6 kg CO₂/kg · Embodied Water 65 L/kg7.8 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA2

A2 Annealed vs A2 HT 57-59 HRC — frequently asked

Is A2 HT 57-59 HRC stronger than A2 Annealed?

Yes. A2 HT 57-59 HRC has a typical yield strength of 1,800 MPa (261 ksi) against 470 MPa (68.2 ksi) for A2 Annealed — about 3.8 times as much. Tensile strength is 2,050 MPa (297 ksi) vs 740 MPa (107 ksi).

Which condition does FabDigit quote by default, Annealed or HT 57-59 HRC?

Annealed is the default A2 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, A2 Annealed or A2 HT 57-59 HRC?

A2 Annealed. Its machinability rates fair (45/100) against not recommended (12/100) for A2 HT 57-59 HRC; for welding the order is A2 Annealed first (poor, 20/100) then A2 HT 57-59 HRC (not recommended, 7/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in A2 Annealed and A2 HT 57-59 HRC side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.