A182 F911 N+T and A182 F911 Q+T are two conditions of the same steel grade, A182 F911: N+T (normalized and tempered) versus Q+T (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. A182 F911 Q+T is the stronger of the two: yield strength 540 MPa (78.3 ksi) against 510 MPa (74 ksi) for A182 F911 N+T, about 6% more. A182 F911 Q+T is harder — 22 HRC against 20 HRC for A182 F911 N+T — which matters for wear surfaces and threads.

A182 F911 Q+TChoose it when strength drives the design, or when surface hardness matters.

A182 F911 N+T vs A182 F911 Q+T: properties

A182 F911 N+TA182 F911 Q+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
730 MPa106 ksi

Yield Strength (0.2% offset)

510 MPa74 ksi
540 MPa78.3 ksi

Elongation at Break

22%
21%

Reduction in Area

62%
60%

Compressive Strength

510 MPa74 ksi
545 MPa79 ksi

Shear Strength

420 MPa60.9 ksi
440 MPa63.8 ksi

Fatigue Strength (Endurance Limit)

320 MPa46.4 ksi
335 MPa48.6 ksi

Fracture Toughness (K_IC)

130 MPa·√m118 ksi·√in
135 MPa·√m123 ksi·√in

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
100 J73.8 ft·lbf

Hardness, Brinell

225 HB
235 HB

Hardness, Rockwell C

20 HRC
22 HRC

Hardness, Vickers

236 HV
248 HV

Same in both: Elastic (Young's) Modulus 215 GPa31.2 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.77 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 26 W/m·K15 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.9 µm/m·K6.1 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 620°C1,148 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.9 % IACS · Electrical Resistivity 6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.55 V · Corrosion Resistance 33 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
37 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
40%

Weldability

40 / 100
38 / 100

Formability (cold)

25 / 100
22 / 100

Same in both: Brazeability / Solderability 30 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.6 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA182 F911

A182 F911 N+T vs A182 F911 Q+T — frequently asked

Is A182 F911 Q+T stronger than A182 F911 N+T?

Yes. A182 F911 Q+T has a typical yield strength of 540 MPa (78.3 ksi) against 510 MPa (74 ksi) for A182 F911 N+T — about 6% more. Tensile strength is 730 MPa (106 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, N+T or Q+T?

N+T is the default A182 F911 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose A182 F911 N+T over A182 F911 Q+T?

Pick A182 F911 Q+T when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A182 F911 N+T and A182 F911 Q+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.