FabDigitFabDigit

Steel 8650-CD vs 8650-HR

Steel · 8650 temper comparison

8650-CD and 8650-HR are two conditions of the same steel grade, 8650: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 8650-CD is the stronger of the two: yield strength 790 MPa (115 ksi) against 550 MPa (79.8 ksi) for 8650-HR, about 44% more; tensile strength follows at 930 MPa (135 ksi) vs 860 MPa (125 ksi). In exchange, 8650-HR is the more ductile: elongation 18% versus 12% for 8650-CD, and 8650-CD is harder (275 HB vs 250 HB). 8650-HR runs hotter in service (400°C vs 320°C continuous).

8650-CDChoose it when strength drives the design.

8650-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

8650-CD vs 8650-HR: properties

8650-CD8650-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

930 MPa135 ksi
860 MPa125 ksi

Yield Strength (0.2% offset)

790 MPa115 ksi
550 MPa79.8 ksi

Elongation at Break

12%
18%

Reduction in Area

35%
40%

Fatigue Strength (Endurance Limit)

430 MPa62.4 ksi
400 MPa58 ksi

Fracture Toughness (K_IC)

60 MPa·√m54.6 ksi·√in
75 MPa·√m68.3 ksi·√in

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
22 J16.2 ft·lbf

Hardness, Brinell

275 HB
250 HB

Hardness, Rockwell C

28 HRC
24 HRC

Hardness, Vickers

289 HV
262 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Shear Strength 560 MPa81.2 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

320°C608 °F
400°C752 °F

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
55%

Weldability

26 / 100
28 / 100

Formability (cold)

22 / 100
30 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 29 MJ/kg12,468 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale8650

8650-CD vs 8650-HR — frequently asked

Is 8650-CD stronger than 8650-HR?

Yes. 8650-CD has a typical yield strength of 790 MPa (115 ksi) against 550 MPa (79.8 ksi) for 8650-HR — about 44% more. Tensile strength is 930 MPa (135 ksi) vs 860 MPa (125 ksi).

Which condition does FabDigit quote by default, CD or HR?

HR is the default 8650 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 8650-CD or 8650-HR?

8650-CD, by a small margin. Both rate fair for machinability — 50/100 against 42/100 for 8650-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8650-CD and 8650-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.