FabDigitFabDigit

Steel 8640-CD vs 8640-CR

Steel · 8640 temper comparison

8640-CD and 8640-CR are two conditions of the same steel grade, 8640: CD (cold drawn) versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. 8640-CD is the stronger of the two: yield strength 760 MPa (110 ksi) against 620 MPa (89.9 ksi) for 8640-CR, about 23% more; tensile strength follows at 895 MPa (130 ksi) vs 760 MPa (110 ksi). 8640-CD is harder — 255 HB against 217 HB for 8640-CR — which matters for wear surfaces and threads. On the shop floor, 8640-CR forms better (30 vs 20 out of 100).

8640-CDChoose it when strength drives the design, or when surface hardness matters.

8640-CD vs 8640-CR: properties

8640-CD8640-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

895 MPa130 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

760 MPa110 ksi
620 MPa89.9 ksi

Elongation at Break

14%
13%

Reduction in Area

42%
35%

Compressive Strength

760 MPa110 ksi
620 MPa89.9 ksi

Shear Strength

535 MPa77.6 ksi
455 MPa66 ksi

Fatigue Strength (Endurance Limit)

400 MPa58 ksi
340 MPa49.3 ksi

Charpy V-Notch Impact (RT)

16 J11.8 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

255 HB
217 HB

Hardness, Rockwell C

25 HRC
17 HRC

Hardness, Vickers

268 HV
228 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Fracture Toughness (K_IC) 75 MPa·√m68.3 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 14 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
60%

Weldability

35 / 100
40 / 100

Formability (cold)

20 / 100
30 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale8640

8640-CD vs 8640-CR — frequently asked

Is 8640-CD stronger than 8640-CR?

Yes. 8640-CD has a typical yield strength of 760 MPa (110 ksi) against 620 MPa (89.9 ksi) for 8640-CR — about 23% more. Tensile strength is 895 MPa (130 ksi) vs 760 MPa (110 ksi).

Which condition does FabDigit quote by default, CD or CR?

HR is the default 8640 condition in the FabDigit quote flow (neither CD nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 8640-CD or 8640-CR?

8640-CR. Its weldability rates fair (40/100) against fair (35/100) for 8640-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8640-CD and 8640-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.