FabDigitFabDigit

Steel 85-N vs 85 QT-50-55HRC

Steel · 85 temper comparison

85-N and 85 QT-50-55HRC are two conditions of the same steel grade, 85: N (normalized) versus QT-50-55HRC. The chemistry is identical, so every difference below comes from the condition. 85 QT-50-55HRC is the stronger of the two: yield strength 1,650 MPa (239 ksi) against 590 MPa (85.6 ksi) for 85-N, about 180% more; tensile strength follows at 1,850 MPa (268 ksi) vs 1,010 MPa (146 ksi). In exchange, 85-N is the more ductile: elongation 11% versus 3% for 85 QT-50-55HRC, and 85 QT-50-55HRC is harder (375 HB vs 300 HB). 85-N runs hotter in service (250°C vs 160°C continuous). On the shop floor, 85-N machines more easily (fair vs not recommended).

85-NChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

85 QT-50-55HRCChoose it when strength drives the design.

85-N vs 85 QT-50-55HRC: properties

85-N85 QT-50-55HRC

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

205 GPa29.7 Msi
207 GPa30 Msi

Tensile Strength (Ultimate)

1,010 MPa146 ksi
1,850 MPa268 ksi

Yield Strength (0.2% offset)

590 MPa85.6 ksi
1,650 MPa239 ksi

Elongation at Break

11%
3%

Reduction in Area

22%
33%

Compressive Strength

1,010 MPa146 ksi
1,150 MPa167 ksi

Shear Strength

630 MPa91.4 ksi
740 MPa107 ksi

Fatigue Strength (Endurance Limit)

450 MPa65.3 ksi
680 MPa98.6 ksi

Fracture Toughness (K_IC)

45 MPa·√m41 ksi·√in
40 MPa·√m36.4 ksi·√in

Charpy V-Notch Impact (RT)

8 J5.9 ft·lbf
5 J3.7 ft·lbf

Hardness, Brinell

300 HB
375 HB

Hardness, Rockwell C

31 HRC
53 HRC

Hardness, Vickers

316 HV
560 HV

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.81 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

47 W/m·K27.2 BTU/hr·ft·°F
46 W/m·K26.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

250°C482 °F
160°C320 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10 % IACS
9.5 % IACS

Electrical Resistivity

1.75×10⁻⁷ Ω·m6.89 µΩ·in
1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
10 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
12%

Formability (cold)

20 / 100
4 / 100

Same in both: Weldability 15 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale85

85-N vs 85 QT-50-55HRC — frequently asked

Is 85 QT-50-55HRC stronger than 85-N?

Yes. 85 QT-50-55HRC has a typical yield strength of 1,650 MPa (239 ksi) against 590 MPa (85.6 ksi) for 85-N — about 180% more. Tensile strength is 1,850 MPa (268 ksi) vs 1,010 MPa (146 ksi).

Which condition does FabDigit quote by default, N or QT-50-55HRC?

QT is the default 85 condition in the FabDigit quote flow (neither N nor QT-50-55HRC). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 85-N or 85 QT-50-55HRC?

85-N. Its machinability rates fair (35/100) against not recommended (10/100) for 85 QT-50-55HRC.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 85-N and 85 QT-50-55HRC side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.