7CrWVMoNb9-6-AW and 7CrWVMoNb9-6 Q+T are two conditions of the same steel grade, 7CrWVMoNb9-6: AW (as-welded deposit) versus Q+T (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. 7CrWVMoNb9-6 Q+T is the stronger of the two: yield strength 520 MPa (75.4 ksi) against 480 MPa (69.6 ksi) for 7CrWVMoNb9-6-AW, about 8% more. 7CrWVMoNb9-6 Q+T is the more ductile: elongation 21% versus 18% for 7CrWVMoNb9-6-AW, and 7CrWVMoNb9-6-AW is harder (285 HB vs 210 HB). On the shop floor, 7CrWVMoNb9-6 Q+T machines more easily (45 vs 35 out of 100).

7CrWVMoNb9-6 Q+TChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

7CrWVMoNb9-6-AW vs 7CrWVMoNb9-6 Q+T: properties

7CrWVMoNb9-6-AW7CrWVMoNb9-6 Q+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
650 MPa94.3 ksi

Yield Strength (0.2% offset)

480 MPa69.6 ksi
520 MPa75.4 ksi

Elongation at Break

18%
21%

Reduction in Area

48%
62%

Compressive Strength

480 MPa69.6 ksi
520 MPa75.4 ksi

Shear Strength

385 MPa55.8 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
310 MPa45 ksi

Fracture Toughness (K_IC)

60 MPa·√m54.6 ksi·√in
115 MPa·√m105 ksi·√in

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
120 J88.5 ft·lbf

Hardness, Brinell

285 HB
210 HB

Hardness, Rockwell B

92 HRB
95 HRB

Hardness, Vickers

300 HV
220 HV

Same in both: Elastic (Young's) Modulus 213 GPa30.9 Msi · Shear Modulus 82 GPa11.9 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,465°C2,669 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

565°C1,049 °F
580°C1,076 °F

Same in both: Thermal Conductivity 29 W/m·K16.8 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Resistivity 2.4×10⁻⁷ Ω·m9.45 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

18 / 100
20 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

38%
50%

Weldability

50 / 100
58 / 100

Formability (cold)

20 / 100
35 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 32 MJ/kg13,758 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale7CrWVMoNb9-6

7CrWVMoNb9-6-AW vs 7CrWVMoNb9-6 Q+T — frequently asked

Is 7CrWVMoNb9-6 Q+T stronger than 7CrWVMoNb9-6-AW?

Yes. 7CrWVMoNb9-6 Q+T has a typical yield strength of 520 MPa (75.4 ksi) against 480 MPa (69.6 ksi) for 7CrWVMoNb9-6-AW — about 8% more. Tensile strength is 650 MPa (94.3 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, AW or Q+T?

N+T is the default 7CrWVMoNb9-6 condition in the FabDigit quote flow (neither AW nor Q+T). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 7CrWVMoNb9-6-AW or 7CrWVMoNb9-6 Q+T?

7CrWVMoNb9-6 Q+T, by a small margin. Both rate fair for machinability — 45/100 against 35/100 for 7CrWVMoNb9-6-AW; for welding the order is 7CrWVMoNb9-6 Q+T first (good, 58/100) then 7CrWVMoNb9-6-AW (fair, 50/100).