FabDigitFabDigit

Steel 70Mn4 +C vs 70Mn4 +S

Steel · 70Mn4 temper comparison

70Mn4 +C and 70Mn4 +S are two conditions of the same steel grade, 70Mn4: +C (cold drawn) versus +S (treated for improved shearability). The chemistry is identical, so every difference below comes from the condition. 70Mn4 +C is the stronger of the two: yield strength 1,000 MPa (145 ksi) against 480 MPa (69.6 ksi) for 70Mn4 +S, about 108% more; tensile strength follows at 1,150 MPa (167 ksi) vs 800 MPa (116 ksi). In exchange, 70Mn4 +S is the more ductile: elongation 10% versus 3% for 70Mn4 +C, and 70Mn4 +C is harder (340 HB vs 250 HB). 70Mn4 +S runs hotter in service (400°C vs 200°C continuous). On the shop floor, 70Mn4 +S machines more easily (fair vs poor).

70Mn4 +CChoose it when strength drives the design.

70Mn4 +SChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

70Mn4 +C vs 70Mn4 +S: properties

70Mn4 +C70Mn4 +S

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,150 MPa167 ksi
800 MPa116 ksi

Yield Strength (0.2% offset)

1,000 MPa145 ksi
480 MPa69.6 ksi

Elongation at Break

3%
10%

Reduction in Area

15%
30%

Shear Strength

750 MPa109 ksi
560 MPa81.2 ksi

Fatigue Strength (Endurance Limit)

480 MPa69.6 ksi
360 MPa52.2 ksi

Charpy V-Notch Impact (RT)

5 J3.7 ft·lbf
12 J8.9 ft·lbf

Hardness, Brinell

340 HB
250 HB

Hardness, Vickers

355 HV
262 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 420 MPa60.9 ksi · Fracture Toughness (K_IC) 45 MPa·√m41 ksi·√in · Hardness, Rockwell B 94 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
400°C752 °F

Same in both: Thermal Conductivity 47 W/m·K27.2 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
52 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
58%

Weldability

10 / 100
15 / 100

Formability (cold)

10 / 100
30 / 100

Same in both: Brazeability / Solderability 50 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale70Mn4

70Mn4 +C vs 70Mn4 +S — frequently asked

Is 70Mn4 +C stronger than 70Mn4 +S?

Yes. 70Mn4 +C has a typical yield strength of 1,000 MPa (145 ksi) against 480 MPa (69.6 ksi) for 70Mn4 +S — about 108% more. Tensile strength is 1,150 MPa (167 ksi) vs 800 MPa (116 ksi).

Which condition does FabDigit quote by default, +C or +S?

+A is the default 70Mn4 condition in the FabDigit quote flow (neither +C nor +S). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 70Mn4 +C or 70Mn4 +S?

70Mn4 +S. Its machinability rates fair (52/100) against poor (30/100) for 70Mn4 +C; for welding the order is 70Mn4 +S first (poor, 15/100) then 70Mn4 +C (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 70Mn4 +C and 70Mn4 +S side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.