FabDigitFabDigit

Steel 6150 Annealed vs 6150-CD

Steel · 6150 temper comparison

6150 Annealed and 6150-CD are two conditions of the same steel grade, 6150: Annealed versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 6150-CD is the stronger of the two: yield strength 750 MPa (109 ksi) against 415 MPa (60.2 ksi) for 6150 Annealed, about 81% more; tensile strength follows at 900 MPa (131 ksi) vs 670 MPa (97.2 ksi). In exchange, 6150 Annealed is the more ductile: elongation 22% versus 10% for 6150-CD, and 6150-CD is harder (265 HB vs 197 HB).

6150 AnnealedChoose it when the part is bent, formed or impact-loaded.

6150-CDChoose it when strength drives the design.

6150 Annealed vs 6150-CD: properties

6150 Annealed6150-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

670 MPa97.2 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
750 MPa109 ksi

Elongation at Break

22%
10%

Reduction in Area

45%
35%

Compressive Strength

620 MPa89.9 ksi
750 MPa109 ksi

Shear Strength

620 MPa89.9 ksi
545 MPa79 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
420 MPa60.9 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

197 HB
265 HB

Hardness, Rockwell C

25 HRC
26 HRC

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

46 W/m·K26.6 BTU/hr·ft·°F
44 W/m·K25.4 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
55%

Weldability

32 / 100
26 / 100

Formability (cold)

55 / 100
22 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 45 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale6150

6150 Annealed vs 6150-CD — frequently asked

Is 6150-CD stronger than 6150 Annealed?

Yes. 6150-CD has a typical yield strength of 750 MPa (109 ksi) against 415 MPa (60.2 ksi) for 6150 Annealed — about 81% more. Tensile strength is 900 MPa (131 ksi) vs 670 MPa (97.2 ksi).

Which condition does FabDigit quote by default, Annealed or CD?

HR is the default 6150 condition in the FabDigit quote flow (neither Annealed nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6150 Annealed or 6150-CD?

6150 Annealed. Its machinability rates good (55/100) against fair (50/100) for 6150-CD; for welding the order is 6150 Annealed first (poor, 32/100) then 6150-CD (poor, 26/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6150 Annealed and 6150-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.