FabDigitFabDigit

Steel 6120-CD vs 6120 N+T

Steel · 6120 temper comparison

6120-CD and 6120 N+T are two conditions of the same steel grade, 6120: CD (cold drawn) versus N+T (normalized and tempered). The chemistry is identical, so every difference below comes from the condition. 6120-CD is the stronger of the two: yield strength 600 MPa (87 ksi) against 420 MPa (60.9 ksi) for 6120 N+T, about 43% more; tensile strength follows at 700 MPa (102 ksi) vs 620 MPa (89.9 ksi). In exchange, 6120 N+T is the more ductile: elongation 27% versus 13% for 6120-CD, and 6120-CD is harder (207 HB vs 180 HB).

6120-CDChoose it when strength drives the design.

6120 N+TChoose it when the part is bent, formed or impact-loaded.

6120-CD vs 6120 N+T: properties

6120-CD6120 N+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

600 MPa87 ksi
420 MPa60.9 ksi

Elongation at Break

13%
27%

Reduction in Area

45%
60%

Shear Strength

400 MPa58 ksi
410 MPa59.5 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
310 MPa45 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
120 J88.5 ft·lbf

Hardness, Brinell

207 HB
180 HB

Hardness, Rockwell B

94 HRB
88 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 425°C797 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.5 % IACS · Electrical Resistivity 2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

65%
60%

Weldability

55 / 100
58 / 100

Formability (cold)

35 / 100
55 / 100

Same in both: Machinability 52 / 100 · Brazeability / Solderability 65 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale6120

6120-CD vs 6120 N+T — frequently asked

Is 6120-CD stronger than 6120 N+T?

Yes. 6120-CD has a typical yield strength of 600 MPa (87 ksi) against 420 MPa (60.9 ksi) for 6120 N+T — about 43% more. Tensile strength is 700 MPa (102 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, CD or N+T?

A is the default 6120 condition in the FabDigit quote flow (neither CD nor N+T). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 6120-CD over 6120 N+T?

Pick 6120-CD when strength drives the design. Pick 6120 N+T when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6120-CD and 6120 N+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.