Steel 60SiCrV7 +H vs 60SiCrV7 +S

Steel · 60SiCrV7 temper comparison

60SiCrV7 +H and 60SiCrV7 +S are two conditions of the same steel grade, 60SiCrV7: +H (hardened (oil quenched, low-temper) / supplied with specified…) versus +S (treated for high shearability). The chemistry is identical, so every difference below comes from the condition. 60SiCrV7 +H is the stronger of the two: yield strength 1,800 MPa (261 ksi) against 470 MPa (68.2 ksi) for 60SiCrV7 +S, about 3.8 times as much; tensile strength follows at 2,150 MPa (312 ksi) vs 760 MPa (110 ksi). In exchange, 60SiCrV7 +S is the more ductile: elongation 16% versus 2% for 60SiCrV7 +H, and 60SiCrV7 +H is harder (480 HB vs 215 HB). 60SiCrV7 +S runs hotter in service (300°C vs 180°C continuous) and 60SiCrV7 +S conducts heat better (40 W/m·K vs 32 W/m·K). On the shop floor, 60SiCrV7 +S machines more easily (fair vs not recommended) and 60SiCrV7 +S welds better (poor vs not recommended).

60SiCrV7 +HChoose it when strength drives the design.

60SiCrV7 +SChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

60SiCrV7 +H vs 60SiCrV7 +S: properties

60SiCrV7 +H60SiCrV7 +S

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

2,150 MPa312 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

1,800 MPa261 ksi
470 MPa68.2 ksi

Elongation at Break

2%
16%

Reduction in Area

8%
45%

Compressive Strength

1,600 MPa232 ksi
480 MPa69.6 ksi

Shear Strength

1,050 MPa152 ksi
500 MPa72.5 ksi

Fatigue Strength (Endurance Limit)

620 MPa89.9 ksi
340 MPa49.3 ksi

Fracture Toughness (K_IC)

20 MPa·√m18.2 ksi·√in
60 MPa·√m54.6 ksi·√in

Charpy V-Notch Impact (RT)

5 J3.7 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

480 HB
215 HB

Hardness, Rockwell C

60 HRC
17 HRC

Hardness, Vickers

700 HV
225 HV

Same in both: Elastic (Young's) Modulus 206 GPa29.9 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

32 W/m·K18.5 BTU/hr·ft·°F
40 W/m·K23.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

180°C356 °F
300°C572 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

4.9 % IACS
5.5 % IACS

Electrical Resistivity

3.5×10⁻⁷ Ω·m13.8 µΩ·in
3.1×10⁻⁷ Ω·m12.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

5 / 100
48 / 100

Machinability Rating (AISI 1212 = 100 %)

4%
48%

Weldability

5 / 100
15 / 100

Formability (cold)

2 / 100
52 / 100

Same in both: Brazeability / Solderability 35 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale60SiCrV7

60SiCrV7 +H vs 60SiCrV7 +S — frequently asked

Is 60SiCrV7 +H stronger than 60SiCrV7 +S?

Yes. 60SiCrV7 +H has a typical yield strength of 1,800 MPa (261 ksi) against 470 MPa (68.2 ksi) for 60SiCrV7 +S — about 3.8 times as much. Tensile strength is 2,150 MPa (312 ksi) vs 760 MPa (110 ksi).

Which condition does FabDigit quote by default, +H or +S?

+QT is the default 60SiCrV7 condition in the FabDigit quote flow (neither +H nor +S). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 60SiCrV7 +H or 60SiCrV7 +S?

60SiCrV7 +S. Its machinability rates fair (48/100) against not recommended (5/100) for 60SiCrV7 +H; for welding the order is 60SiCrV7 +S first (poor, 15/100) then 60SiCrV7 +H (not recommended, 5/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 60SiCrV7 +H and 60SiCrV7 +S side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.