FabDigitFabDigit

Steel 56Mn4 +N vs 56Mn4 +S

Steel · 56Mn4 temper comparison

56Mn4 +N and 56Mn4 +S are two conditions of the same steel grade, 56Mn4: +N (normalized) versus +S (treated for high shearability). The chemistry is identical, so every difference below comes from the condition. 56Mn4 +N is the stronger of the two: yield strength 480 MPa (69.6 ksi) against 380 MPa (55.1 ksi) for 56Mn4 +S, about 26% more; tensile strength follows at 800 MPa (116 ksi) vs 650 MPa (94.3 ksi). In exchange, 56Mn4 +S is the more ductile: elongation 17% versus 13% for 56Mn4 +N, and 56Mn4 +N is harder (235 HB vs 195 HB).

56Mn4 +NChoose it when strength drives the design.

56Mn4 +SChoose it when the part is bent, formed or impact-loaded.

56Mn4 +N vs 56Mn4 +S: properties

56Mn4 +N56Mn4 +S

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

800 MPa116 ksi
650 MPa94.3 ksi

Yield Strength (0.2% offset)

480 MPa69.6 ksi
380 MPa55.1 ksi

Elongation at Break

13%
17%

Reduction in Area

32%
38%

Shear Strength

430 MPa62.4 ksi
410 MPa59.5 ksi

Fatigue Strength (Endurance Limit)

360 MPa52.2 ksi
295 MPa42.8 ksi

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
22 J16.2 ft·lbf

Hardness, Brinell

235 HB
195 HB

Hardness, Rockwell B

94 HRB
92 HRB

Hardness, Vickers

248 HV
205 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 400 MPa58 ksi · Fracture Toughness (K_IC) 55 MPa·√m50.1 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 46 W/m·K26.6 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8.5 % IACS · Electrical Resistivity 2×10⁻⁷ Ω·m7.87 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

52%
58%

Formability (cold)

35 / 100
50 / 100

Same in both: Weldability 25 / 100 · Castability 55 / 100 · Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 42 L/kg5 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale56Mn4

56Mn4 +N vs 56Mn4 +S — frequently asked

Is 56Mn4 +N stronger than 56Mn4 +S?

Yes. 56Mn4 +N has a typical yield strength of 480 MPa (69.6 ksi) against 380 MPa (55.1 ksi) for 56Mn4 +S — about 26% more. Tensile strength is 800 MPa (116 ksi) vs 650 MPa (94.3 ksi).

Which condition does FabDigit quote by default, +N or +S?

+A is the default 56Mn4 condition in the FabDigit quote flow (neither +N nor +S). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 56Mn4 +N or 56Mn4 +S?

56Mn4 +S, by a small margin. Both rate fair for machinability — 50/100 against 45/100 for 56Mn4 +N.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 56Mn4 +N and 56Mn4 +S side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.