FabDigitFabDigit

Steel 5155-CD vs 5155-HR

Steel · 5155 temper comparison

5155-CD and 5155-HR are two conditions of the same steel grade, 5155: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 5155-CD is the stronger of the two: yield strength 760 MPa (110 ksi) against 530 MPa (76.9 ksi) for 5155-HR, about 43% more. In exchange, 5155-HR is the more ductile: elongation 17% versus 11% for 5155-CD, and 5155-CD is harder (270 HB vs 255 HB). 5155-HR runs hotter in service (400°C vs 300°C continuous).

5155-CDChoose it when strength drives the design.

5155-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5155-CD vs 5155-HR: properties

5155-CD5155-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Yield Strength (0.2% offset)

760 MPa110 ksi
530 MPa76.9 ksi

Elongation at Break

11%
17%

Reduction in Area

35%
40%

Compressive Strength

780 MPa113 ksi
550 MPa79.8 ksi

Shear Strength

560 MPa81.2 ksi
550 MPa79.8 ksi

Fatigue Strength (Endurance Limit)

400 MPa58 ksi
410 MPa59.5 ksi

Fracture Toughness (K_IC)

68 MPa·√m61.9 ksi·√in
75 MPa·√m68.3 ksi·√in

Charpy V-Notch Impact (RT)

16 J11.8 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

270 HB
255 HB

Hardness, Rockwell C

27 HRC
25 HRC

Hardness, Vickers

285 HV
268 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Tensile Strength (Ultimate) 900 MPa131 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
400°C752 °F

Same in both: Thermal Conductivity 46 W/m·K26.6 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.15×10⁻⁷ Ω·m8.46 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
50%

Weldability

20 / 100
25 / 100

Formability (cold)

25 / 100
30 / 100

Same in both: Brazeability / Solderability 30 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale5155

5155-CD vs 5155-HR — frequently asked

Is 5155-CD stronger than 5155-HR?

Yes. 5155-CD has a typical yield strength of 760 MPa (110 ksi) against 530 MPa (76.9 ksi) for 5155-HR — about 43% more. Tensile strength is 900 MPa (131 ksi) vs 900 MPa (131 ksi).

Which condition does FabDigit quote by default, CD or HR?

QT 44-48 HRC is the default 5155 condition in the FabDigit quote flow (neither CD nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5155-CD or 5155-HR?

5155-CD, by a small margin. Both rate fair for machinability — 50/100 against 45/100 for 5155-HR; for welding the order is 5155-HR first (poor, 25/100) then 5155-CD (poor, 20/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5155-CD and 5155-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.