FabDigitFabDigit

Steel 5145-IH vs 5145-N

Steel · 5145 temper comparison

5145-IH and 5145-N are two conditions of the same steel grade, 5145: IH (induction hardened) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 5145-IH is the stronger of the two: yield strength 870 MPa (126 ksi) against 500 MPa (72.5 ksi) for 5145-N, about 74% more; tensile strength follows at 1,000 MPa (145 ksi) vs 830 MPa (120 ksi). In exchange, 5145-N is the more ductile: elongation 20% versus 14% for 5145-IH, and 5145-IH is harder (580 HB vs 240 HB). 5145-N runs hotter in service (400°C vs 180°C continuous). On the shop floor, 5145-N machines more easily (fair vs poor) and 5145-N welds better (fair vs not recommended).

5145-IHChoose it when strength drives the design.

5145-NChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5145-IH vs 5145-N: properties

5145-IH5145-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,000 MPa145 ksi
830 MPa120 ksi

Yield Strength (0.2% offset)

870 MPa126 ksi
500 MPa72.5 ksi

Elongation at Break

14%
20%

Reduction in Area

45%
50%

Compressive Strength

900 MPa131 ksi
345 MPa50 ksi

Shear Strength

600 MPa87 ksi
520 MPa75.4 ksi

Fatigue Strength (Endurance Limit)

600 MPa87 ksi
375 MPa54.4 ksi

Fracture Toughness (K_IC)

55 MPa·√m50.1 ksi·√in
85 MPa·√m77.4 ksi·√in

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
38 J28 ft·lbf

Hardness, Brinell

580 HB
240 HB

Hardness, Vickers

650 HV
250 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Rockwell B 88 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

44 W/m·K25.4 BTU/hr·ft·°F
46 W/m·K26.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

180°C356 °F
400°C752 °F

Same in both: Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.4 % IACS
7.8 % IACS

Electrical Resistivity

2.33×10⁻⁷ Ω·m9.17 µΩ·in
2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

11 / 100
12 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

15 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

15%
50%

Weldability

10 / 100
35 / 100

Formability (cold)

5 / 100
45 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale5145

5145-IH vs 5145-N — frequently asked

Is 5145-IH stronger than 5145-N?

Yes. 5145-IH has a typical yield strength of 870 MPa (126 ksi) against 500 MPa (72.5 ksi) for 5145-N — about 74% more. Tensile strength is 1,000 MPa (145 ksi) vs 830 MPa (120 ksi).

Which condition does FabDigit quote by default, IH or N?

A is the default 5145 condition in the FabDigit quote flow (neither IH nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5145-IH or 5145-N?

5145-N. Its machinability rates fair (50/100) against poor (15/100) for 5145-IH; for welding the order is 5145-N first (fair, 35/100) then 5145-IH (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5145-IH and 5145-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.