Steel · 51100 temper comparison

51100-CD and 51100-HR are two conditions of the same steel grade, 51100: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 51100-CD is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 550 MPa (79.8 ksi) for 51100-HR, about 13% more. In exchange, 51100-HR is the more ductile: elongation 12% versus 10% for 51100-CD, and 51100-HR is harder (270 HB vs 223 HB). 51100-HR runs hotter in service (400°C vs 250°C continuous). On the shop floor, 51100-CD machines more easily (fair vs poor).

51100-CDChoose it when strength drives the design, or when the part is machined in volume.

51100-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

51100-CD vs 51100-HR: properties

51100-CD51100-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

760 MPa110 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
550 MPa79.8 ksi

Elongation at Break

10%
12%

Reduction in Area

30%
28%

Compressive Strength

640 MPa92.8 ksi
570 MPa82.7 ksi

Shear Strength

460 MPa66.7 ksi
540 MPa78.3 ksi

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
400 MPa58 ksi

Fracture Toughness (K_IC)

40 MPa·√m36.4 ksi·√in
35 MPa·√m31.9 ksi·√in

Charpy V-Notch Impact (RT)

9 J6.6 ft·lbf
11 J8.1 ft·lbf

Hardness, Brinell

223 HB
270 HB

Hardness, Rockwell B

98 HRB
102 HRB

Hardness, Vickers

235 HV
284 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.81 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,415°C2,579 °F · Liquidus Temperature 1,460°C2,660 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

250°C482 °F
400°C752 °F

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

48 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
25%

Formability (cold)

25 / 100
20 / 100

Same in both: Weldability 10 / 100 · Castability 30 / 100 · Brazeability / Solderability 35 / 100 · Polishability 88 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.4 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale51100

51100-CD vs 51100-HR — frequently asked

Is 51100-CD stronger than 51100-HR?

Yes. 51100-CD has a typical yield strength of 620 MPa (89.9 ksi) against 550 MPa (79.8 ksi) for 51100-HR — about 13% more. Tensile strength is 760 MPa (110 ksi) vs 900 MPa (131 ksi).

Which condition does FabDigit quote by default, CD or HR?

Annealed is the default 51100 condition in the FabDigit quote flow (neither CD nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 51100-CD or 51100-HR?

51100-CD. Its machinability rates fair (48/100) against poor (28/100) for 51100-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 51100-CD and 51100-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.