FabDigitFabDigit

Steel 50CrVA-QT vs 50CrVA-QT45

Steel · 50CrVA temper comparison

50CrVA-QT and 50CrVA-QT45 are two conditions of the same steel grade, 50CrVA: QT (quenched and tempered) versus QT45 (Q&T 45–48 HRC). The chemistry is identical, so every difference below comes from the condition. 50CrVA-QT45 is the stronger of the two: yield strength 1,420 MPa (206 ksi) against 1,200 MPa (174 ksi) for 50CrVA-QT, about 18% more; tensile strength follows at 1,570 MPa (228 ksi) vs 1,350 MPa (196 ksi). In exchange, 50CrVA-QT is the more ductile: elongation 12% versus 9% for 50CrVA-QT45, and 50CrVA-QT45 is harder (435 HB vs 400 HB). 50CrVA-QT runs hotter in service (250°C vs 230°C continuous).

50CrVA-QTChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

50CrVA-QT45Choose it when strength drives the design.

50CrVA-QT vs 50CrVA-QT45: properties

50CrVA-QT50CrVA-QT45

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,350 MPa196 ksi
1,570 MPa228 ksi

Yield Strength (0.2% offset)

1,200 MPa174 ksi
1,420 MPa206 ksi

Elongation at Break

12%
9%

Reduction in Area

45%
38%

Shear Strength

810 MPa117 ksi
940 MPa136 ksi

Fatigue Strength (Endurance Limit)

650 MPa94.3 ksi
700 MPa102 ksi

Fracture Toughness (K_IC)

70 MPa·√m63.7 ksi·√in
58 MPa·√m52.8 ksi·√in

Charpy V-Notch Impact (RT)

32 J23.6 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

400 HB
435 HB

Hardness, Rockwell C

43 HRC
46 HRC

Hardness, Vickers

425 HV
465 HV

Same in both: Elastic (Young's) Modulus 206 GPa29.9 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 1,230 MPa178 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

250°C482 °F
230°C446 °F

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
24 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
25%

Same in both: Weldability 22 / 100 · Formability (cold) 12 / 100 · Brazeability / Solderability 45 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 31 MJ/kg13,328 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale50CrVA

50CrVA-QT vs 50CrVA-QT45 — frequently asked

Is 50CrVA-QT45 stronger than 50CrVA-QT?

Yes. 50CrVA-QT45 has a typical yield strength of 1,420 MPa (206 ksi) against 1,200 MPa (174 ksi) for 50CrVA-QT — about 18% more. Tensile strength is 1,570 MPa (228 ksi) vs 1,350 MPa (196 ksi).

Which condition does FabDigit quote by default, QT or QT45?

QT is the default 50CrVA condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 50CrVA-QT or 50CrVA-QT45?

50CrVA-QT, by a small margin. Both rate poor for machinability — 32/100 against 24/100 for 50CrVA-QT45.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 50CrVA-QT and 50CrVA-QT45 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.