Steel · 50CrVA temper comparison

50CrVA-A and 50CrVA-CD are two conditions of the same steel grade, 50CrVA: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 50CrVA-CD is the stronger of the two: yield strength 720 MPa (104 ksi) against 500 MPa (72.5 ksi) for 50CrVA-A, about 44% more; tensile strength follows at 900 MPa (131 ksi) vs 780 MPa (113 ksi). In exchange, 50CrVA-A is the more ductile: elongation 20% versus 9% for 50CrVA-CD, and 50CrVA-CD is harder (265 HB vs 225 HB).

50CrVA-AChoose it when the part is bent, formed or impact-loaded.

50CrVA-CDChoose it when strength drives the design.

50CrVA-A vs 50CrVA-CD: properties

50CrVA-A50CrVA-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

780 MPa113 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

500 MPa72.5 ksi
720 MPa104 ksi

Elongation at Break

20%
9%

Reduction in Area

45%
35%

Compressive Strength

1,230 MPa178 ksi
820 MPa119 ksi

Shear Strength

470 MPa68.2 ksi
540 MPa78.3 ksi

Fatigue Strength (Endurance Limit)

350 MPa50.8 ksi
410 MPa59.5 ksi

Fracture Toughness (K_IC)

70 MPa·√m63.7 ksi·√in
55 MPa·√m50.1 ksi·√in

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

225 HB
265 HB

Hardness, Rockwell C

43 HRC
27 HRC

Hardness, Vickers

235 HV
280 HV

Same in both: Elastic (Young's) Modulus 206 GPa29.9 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
55%

Weldability

28 / 100
24 / 100

Formability (cold)

45 / 100
30 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 31 MJ/kg13,328 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale50CrVA

50CrVA-A vs 50CrVA-CD — frequently asked

Is 50CrVA-CD stronger than 50CrVA-A?

Yes. 50CrVA-CD has a typical yield strength of 720 MPa (104 ksi) against 500 MPa (72.5 ksi) for 50CrVA-A — about 44% more. Tensile strength is 900 MPa (131 ksi) vs 780 MPa (113 ksi).

Which condition does FabDigit quote by default, A or CD?

QT is the default 50CrVA condition in the FabDigit quote flow (neither A nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 50CrVA-A or 50CrVA-CD?

50CrVA-A. Its machinability rates good (55/100) against fair (50/100) for 50CrVA-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 50CrVA-A and 50CrVA-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.