Steel · 50B60 temper comparison

50B60-CD and 50B60-QT205 are two conditions of the same steel grade, 50B60: CD (cold drawn) versus QT205 (Q&T). The chemistry is identical, so every difference below comes from the condition. 50B60-QT205 is the stronger of the two: yield strength 1,780 MPa (258 ksi) against 700 MPa (102 ksi) for 50B60-CD, about 154% more; tensile strength follows at 2,000 MPa (290 ksi) vs 830 MPa (120 ksi). In exchange, 50B60-CD is the more ductile: elongation 10% versus 8% for 50B60-QT205, and 50B60-QT205 is harder (627 HB vs 241 HB). 50B60-CD runs hotter in service (400°C vs 160°C continuous). On the shop floor, 50B60-CD machines more easily (fair vs not recommended) and 50B60-CD welds better (poor vs not recommended).

50B60-CDChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

50B60-QT205Choose it when strength drives the design.

50B60-CD vs 50B60-QT205: properties

50B60-CD50B60-QT205

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

830 MPa120 ksi
2,000 MPa290 ksi

Yield Strength (0.2% offset)

700 MPa102 ksi
1,780 MPa258 ksi

Elongation at Break

10%
8%

Reduction in Area

30%
25%

Shear Strength

540 MPa78.3 ksi
1,200 MPa174 ksi

Fatigue Strength (Endurance Limit)

370 MPa53.7 ksi
700 MPa102 ksi

Fracture Toughness (K_IC)

55 MPa·√m50.1 ksi·√in
30 MPa·√m27.3 ksi·√in

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
9 J6.6 ft·lbf

Hardness, Brinell

241 HB
627 HB

Hardness, Vickers

228 HV
660 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 420 MPa60.9 ksi · Hardness, Rockwell B 96 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
160°C320 °F

Same in both: Thermal Conductivity 46 W/m·K26.6 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8.6 % IACS · Electrical Resistivity 2×10⁻⁷ Ω·m7.87 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
12 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
15%

Weldability

25 / 100
10 / 100

Formability (cold)

25 / 100
5 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale50B60

50B60-CD vs 50B60-QT205 — frequently asked

Is 50B60-QT205 stronger than 50B60-CD?

Yes. 50B60-QT205 has a typical yield strength of 1,780 MPa (258 ksi) against 700 MPa (102 ksi) for 50B60-CD — about 154% more. Tensile strength is 2,000 MPa (290 ksi) vs 830 MPa (120 ksi).

Which condition does FabDigit quote by default, CD or QT205?

A is the default 50B60 condition in the FabDigit quote flow (neither CD nor QT205). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 50B60-CD or 50B60-QT205?

50B60-CD. Its machinability rates fair (50/100) against not recommended (12/100) for 50B60-QT205; for welding the order is 50B60-CD first (poor, 25/100) then 50B60-QT205 (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 50B60-CD and 50B60-QT205 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.