FabDigitFabDigit

Steel 5015-CD vs 5015-N

Steel · 5015 temper comparison

5015-CD and 5015-N are two conditions of the same steel grade, 5015: CD (cold drawn) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 5015-CD is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 315 MPa (45.7 ksi) for 5015-N, about 43% more; tensile strength follows at 525 MPa (76.1 ksi) vs 470 MPa (68.2 ksi). In exchange, 5015-N is the more ductile: elongation 28% versus 15% for 5015-CD, and 5015-CD is harder (149 HB vs 137 HB). 5015-N runs hotter in service (400°C vs 350°C continuous).

5015-CDChoose it when strength drives the design.

5015-NChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5015-CD vs 5015-N: properties

5015-CD5015-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

525 MPa76.1 ksi
470 MPa68.2 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
315 MPa45.7 ksi

Elongation at Break

15%
28%

Reduction in Area

45%
60%

Shear Strength

340 MPa49.3 ksi
320 MPa46.4 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
225 MPa32.6 ksi

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
100 J73.8 ft·lbf

Hardness, Brinell

149 HB
137 HB

Hardness, Rockwell B

80 HRB
75 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
400°C752 °F

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.5 % IACS · Electrical Resistivity 1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

63 / 100
57 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
58%

Weldability

74 / 100
78 / 100

Formability (cold)

45 / 100
62 / 100

Same in both: Brazeability / Solderability 70 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale5015

5015-CD vs 5015-N — frequently asked

Is 5015-CD stronger than 5015-N?

Yes. 5015-CD has a typical yield strength of 450 MPa (65.3 ksi) against 315 MPa (45.7 ksi) for 5015-N — about 43% more. Tensile strength is 525 MPa (76.1 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, CD or N?

A is the default 5015 condition in the FabDigit quote flow (neither CD nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5015-CD or 5015-N?

5015-CD, by a small margin. Both rate good for machinability — 63/100 against 57/100 for 5015-N.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5015-CD and 5015-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.