Steel · 50# temper comparison

50#-HR and 50#-QT are two conditions of the same steel grade, 50#: HR (hot rolled) versus QT (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. 50#-QT is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 400 MPa (58 ksi) for 50#-HR, about 55% more; tensile strength follows at 850 MPa (123 ksi) vs 700 MPa (102 ksi). 50#-QT is harder — 250 HB against 210 HB for 50#-HR — which matters for wear surfaces and threads. On the shop floor, 50#-HR welds better (fair vs poor).

50#-HRChoose it when it will be welded.

50#-QTChoose it when strength drives the design, or when surface hardness matters.

50#-HR vs 50#-QT: properties

50#-HR50#-QT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
850 MPa123 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
620 MPa89.9 ksi

Reduction in Area

45%
48%

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
390 MPa56.6 ksi

Fracture Toughness (K_IC)

45 MPa·√m41 ksi·√in
60 MPa·√m54.6 ksi·√in

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

210 HB
250 HB

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Elongation at Break 16% · Compressive Strength 400 MPa58 ksi · Shear Strength 420 MPa60.9 ksi · Hardness, Rockwell B 94 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.5 % IACS · Electrical Resistivity 1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
45%

Weldability

35 / 100
25 / 100

Same in both: Formability (cold) 35 / 100 · Castability 45 / 100 · Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale50#

50#-HR vs 50#-QT — frequently asked

Is 50#-QT stronger than 50#-HR?

Yes. 50#-QT has a typical yield strength of 620 MPa (89.9 ksi) against 400 MPa (58 ksi) for 50#-HR — about 55% more. Tensile strength is 850 MPa (123 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, HR or QT?

HR is the default 50# condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 50#-HR or 50#-QT?

50#-HR, by a small margin. Both rate fair for machinability — 50/100 against 45/100 for 50#-QT; for welding the order is 50#-HR first (fair, 35/100) then 50#-QT (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 50#-HR and 50#-QT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.