FabDigitFabDigit

Steel 4J50-CD vs 4J50-SR

Steel · 4J50 temper comparison

4J50-CD and 4J50-SR are two conditions of the same steel grade, 4J50: CD (cold drawn) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. 4J50-CD is the stronger of the two: yield strength 520 MPa (75.4 ksi) against 400 MPa (58 ksi) for 4J50-SR, about 30% more; tensile strength follows at 660 MPa (95.7 ksi) vs 580 MPa (84.1 ksi). In exchange, 4J50-SR is the more ductile: elongation 20% versus 12% for 4J50-CD, and 4J50-CD is harder (200 HB vs 168 HB). 4J50-SR runs hotter in service (450°C vs 350°C continuous).

4J50-CDChoose it when strength drives the design.

4J50-SRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

4J50-CD vs 4J50-SR: properties

4J50-CD4J50-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

152 GPa22 Msi
150 GPa21.8 Msi

Tensile Strength (Ultimate)

660 MPa95.7 ksi
580 MPa84.1 ksi

Yield Strength (0.2% offset)

520 MPa75.4 ksi
400 MPa58 ksi

Elongation at Break

12%
20%

Reduction in Area

40%
50%

Shear Strength

410 MPa59.5 ksi
360 MPa52.2 ksi

Fatigue Strength (Endurance Limit)

290 MPa42.1 ksi
260 MPa37.7 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

200 HB
168 HB

Hardness, Rockwell B

93 HRB
87 HRB

Hardness, Vickers

210 HV
175 HV

Same in both: Shear Modulus 58 GPa8.4 Msi · Bulk Modulus 120 GPa17.4 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 8.2 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
450°C842 °F

Same in both: Thermal Conductivity 13.5 W/m·K7.8 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 9.5 µm/m·K5.3 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 4 % IACS · Electrical Resistivity 4.3×10⁻⁷ Ω·m16.9 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 32 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

38%
34%

Weldability

65 / 100
68 / 100

Formability (cold)

50 / 100
62 / 100

Same in both: Brazeability / Solderability 80 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 80 MJ/kg34,394 BTU/lb · Embodied Carbon (primary production) 7 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4J50

4J50-CD vs 4J50-SR — frequently asked

Is 4J50-CD stronger than 4J50-SR?

Yes. 4J50-CD has a typical yield strength of 520 MPa (75.4 ksi) against 400 MPa (58 ksi) for 4J50-SR — about 30% more. Tensile strength is 660 MPa (95.7 ksi) vs 580 MPa (84.1 ksi).

Which condition does FabDigit quote by default, CD or SR?

M is the default 4J50 condition in the FabDigit quote flow (neither CD nor SR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4J50-CD or 4J50-SR?

4J50-CD, by a small margin. Both rate fair for machinability — 45/100 against 40/100 for 4J50-SR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4J50-CD and 4J50-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.