Steel 4620-CR vs 4620 Q&T
Steel · 4620 temper comparison
4620-CR and 4620 Q&T are two conditions of the same steel grade, 4620: CR (cold rolled) versus Q&T (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. 4620 Q&T is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 540 MPa (78.3 ksi) for 4620-CR, about 15% more; tensile strength follows at 800 MPa (116 ksi) vs 640 MPa (92.8 ksi). 4620 Q&T is the more ductile: elongation 18% versus 14% for 4620-CR, and 4620 Q&T is harder (240 HB vs 187 HB). 4620 Q&T runs hotter in service (400°C vs 350°C continuous). On the shop floor, 4620-CR machines more easily (good vs fair) and 4620-CR welds better (good vs fair).
4620-CRChoose it when the part is machined in volume, or when it will be welded.
4620 Q&TChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.
4620-CR vs 4620 Q&T: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Shear Strength
Fatigue Strength (Endurance Limit)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell B
Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29
Physical
Density and transition temperatures.
Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F
Thermal
How each material carries heat and how hot it can run.
Max Service Temperature (continuous)
Same in both: Thermal Conductivity 46 W/m·K26.6 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -50°C-58 °F
Electrical
Conductivity and insulation.
Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Brazeability / Solderability 70 / 100 · Polishability 55 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 29 MJ/kg12,468 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 30%
Strength versus weight
Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
4620-CR vs 4620 Q&T — frequently asked
Is 4620 Q&T stronger than 4620-CR?
Yes. 4620 Q&T has a typical yield strength of 620 MPa (89.9 ksi) against 540 MPa (78.3 ksi) for 4620-CR — about 15% more. Tensile strength is 800 MPa (116 ksi) vs 640 MPa (92.8 ksi).
Which condition does FabDigit quote by default, CR or Q&T?
HR is the default 4620 condition in the FabDigit quote flow (neither CR nor Q&T). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, 4620-CR or 4620 Q&T?
4620-CR. Its machinability rates good (60/100) against fair (48/100) for 4620 Q&T; for welding the order is 4620-CR first (good, 60/100) then 4620 Q&T (fair, 50/100).
Ready to make it?
Upload a CAD file and FabDigit prices the part in 4620-CR and 4620 Q&T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.
