FabDigitFabDigit

Steel 420 Mod Mold Q&T vs 420 Mod Mold Q&T 52-54

Steel · 420 Mod Mold temper comparison

420 Mod Mold Q&T and 420 Mod Mold Q&T 52-54 are two conditions of the same steel grade, 420 Mod Mold: Q&T (quenched and tempered) versus Q&T 52-54 (Q&T 52–54 HRC). The chemistry is identical, so every difference below comes from the condition. 420 Mod Mold Q&T 52-54 is the stronger of the two: yield strength 1,600 MPa (232 ksi) against 1,450 MPa (210 ksi) for 420 Mod Mold Q&T, about 10% more; tensile strength follows at 1,900 MPa (276 ksi) vs 1,750 MPa (254 ksi). In exchange, 420 Mod Mold Q&T is the more ductile: elongation 7% versus 4% for 420 Mod Mold Q&T 52-54, and 420 Mod Mold Q&T 52-54 is harder (590 HV vs 540 HV). 420 Mod Mold Q&T runs hotter in service (250°C vs 200°C continuous). On the shop floor, 420 Mod Mold Q&T 52-54 welds better (25 vs 15 out of 100).

420 Mod Mold Q&TChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

420 Mod Mold Q&T 52-54Choose it when strength drives the design, or when it will be welded.

420 Mod Mold Q&T vs 420 Mod Mold Q&T 52-54: properties

420 Mod Mold Q&T420 Mod Mold Q&T 52-54

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,750 MPa254 ksi
1,900 MPa276 ksi

Yield Strength (0.2% offset)

1,450 MPa210 ksi
1,600 MPa232 ksi

Elongation at Break

7%
4%

Reduction in Area

25%
50%

Compressive Strength

1,900 MPa276 ksi
500 MPa72.5 ksi

Shear Strength

1,050 MPa152 ksi
460 MPa66.7 ksi

Fatigue Strength (Endurance Limit)

700 MPa102 ksi
350 MPa50.8 ksi

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
9 J6.6 ft·lbf

Hardness, Vickers

540 HV
590 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 78 GPa11.3 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Brinell 220 HB · Hardness, Rockwell B 97 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.75 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

250°C482 °F
200°C392 °F

Same in both: Thermal Conductivity 24 W/m·K13.9 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.5 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 3.1 % IACS · Electrical Resistivity 5.5×10⁻⁷ Ω·m21.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
56 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.35 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

20 / 100
14 / 100

Machinability Rating (AISI 1212 = 100 %)

18%
12%

Weldability

15 / 100
25 / 100

Polishability

93 / 100
95 / 100

Same in both: Formability (cold) 35 / 100 · Brazeability / Solderability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 95 L/kg11.4 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale420 Mod Mold

420 Mod Mold Q&T vs 420 Mod Mold Q&T 52-54 — frequently asked

Is 420 Mod Mold Q&T 52-54 stronger than 420 Mod Mold Q&T?

Yes. 420 Mod Mold Q&T 52-54 has a typical yield strength of 1,600 MPa (232 ksi) against 1,450 MPa (210 ksi) for 420 Mod Mold Q&T — about 10% more. Tensile strength is 1,900 MPa (276 ksi) vs 1,750 MPa (254 ksi).

Which condition does FabDigit quote by default, Q&T or Q&T 52-54?

Annealed is the default 420 Mod Mold condition in the FabDigit quote flow (neither Q&T nor Q&T 52-54). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 420 Mod Mold Q&T or 420 Mod Mold Q&T 52-54?

420 Mod Mold Q&T. Its machinability rates poor (20/100) against not recommended (14/100) for 420 Mod Mold Q&T 52-54; for welding the order is 420 Mod Mold Q&T 52-54 first (poor, 25/100) then 420 Mod Mold Q&T (poor, 15/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 420 Mod Mold Q&T and 420 Mod Mold Q&T 52-54 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.