FabDigitFabDigit

Steel 4147-CD vs 4147-IH

Steel · 4147 temper comparison

4147-CD and 4147-IH are two conditions of the same steel grade, 4147: CD (cold drawn) versus IH (induction hardened). The chemistry is identical, so every difference below comes from the condition. 4147-IH is the stronger of the two: yield strength 860 MPa (125 ksi) against 670 MPa (97.2 ksi) for 4147-CD, about 28% more; tensile strength follows at 965 MPa (140 ksi) vs 790 MPa (115 ksi). 4147-IH is harder — 600 HB against 235 HB for 4147-CD — which matters for wear surfaces and threads. 4147-CD runs hotter in service (400°C vs 200°C continuous). On the shop floor, 4147-CD machines more easily (good vs not recommended), 4147-CD welds better (poor vs not recommended), and 4147-CD forms better (poor vs not recommended).

4147-CDChoose it when the part sees heat, or when the part is machined in volume.

4147-IHChoose it when strength drives the design, or when surface hardness matters.

4147-CD vs 4147-IH: properties

4147-CD4147-IH

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

790 MPa115 ksi
965 MPa140 ksi

Yield Strength (0.2% offset)

670 MPa97.2 ksi
860 MPa125 ksi

Elongation at Break

14%
15%

Reduction in Area

42%
45%

Compressive Strength

685 MPa99.4 ksi
1,750 MPa254 ksi

Shear Strength

475 MPa68.9 ksi
620 MPa89.9 ksi

Fatigue Strength (Endurance Limit)

390 MPa56.6 ksi
620 MPa89.9 ksi

Fracture Toughness (K_IC)

68 MPa·√m61.9 ksi·√in
42 MPa·√m38.2 ksi·√in

Charpy V-Notch Impact (RT)

24 J17.7 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

235 HB
600 HB

Hardness, Rockwell C

21 HRC
57 HRC

Hardness, Vickers

247 HV
640 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,416°C2,581 °F · Liquidus Temperature 1,485°C2,705 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

42.6 W/m·K24.6 BTU/hr·ft·°F
42 W/m·K24.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
200°C392 °F

Same in both: Specific Heat Capacity 473 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.8 % IACS
7.5 % IACS

Electrical Resistivity

2.2×10⁻⁷ Ω·m8.66 µΩ·in
2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
12 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
10%

Weldability

28 / 100
8 / 100

Formability (cold)

18 / 100
5 / 100

Same in both: Castability 20 / 100 · Brazeability / Solderability 55 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 29 MJ/kg12,468 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4147

4147-CD vs 4147-IH — frequently asked

Is 4147-IH stronger than 4147-CD?

Yes. 4147-IH has a typical yield strength of 860 MPa (125 ksi) against 670 MPa (97.2 ksi) for 4147-CD — about 28% more. Tensile strength is 965 MPa (140 ksi) vs 790 MPa (115 ksi).

Which condition does FabDigit quote by default, CD or IH?

QT2832 is the default 4147 condition in the FabDigit quote flow (neither CD nor IH). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4147-CD or 4147-IH?

4147-CD. Its machinability rates good (58/100) against not recommended (12/100) for 4147-IH; for welding the order is 4147-CD first (poor, 28/100) then 4147-IH (not recommended, 8/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4147-CD and 4147-IH side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.