FabDigitFabDigit

Steel 4145 vs 4815

Steel · grade comparison

Steel 4145 and 4815 are both steel grades. 4145 is the stronger of the two: yield strength 520 MPa (75.4 ksi) against 420 MPa (60.9 ksi) for 4815, about 24% more; tensile strength follows at 830 MPa (120 ksi) vs 690 MPa (100 ksi). In exchange, 4815 is the more ductile: elongation 22% versus 18% for 4145, and 4145 is harder (235 HB vs 200 HB). 4145 conducts heat better (43 W/m·K vs 35 W/m·K). On the shop floor, 4815 welds better (good vs fair).

4145Choose it when strength drives the design.

4815Choose it when the part is bent, formed or impact-loaded, or when it will be welded.

4145 vs 4815: properties

41454815

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

830 MPa120 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

520 MPa75.4 ksi
420 MPa60.9 ksi

Elongation at Break

18%
22%

Reduction in Area

45%
50%

Compressive Strength

540 MPa78.3 ksi
420 MPa60.9 ksi

Shear Strength

500 MPa72.5 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

370 MPa53.7 ksi
310 MPa45 ksi

Charpy V-Notch Impact (RT)

28 J20.7 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

235 HB
200 HB

Hardness, Rockwell B

99 HRB
93 HRB

Hardness, Rockwell C

22 HRC
—

Hardness, Vickers

247 HV
210 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Fracture Toughness (K_IC) 95 MPa·√m86.5 ksi·√in

Physical

Density and transition temperatures.

Density

7.85 g/cm³0.28 lb/in³
7.87 g/cm³0.28 lb/in³

Melting Point (Solidus)

1,416°C2,581 °F
1,425°C2,597 °F

Liquidus Temperature

1,480°C2,696 °F
1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

43 W/m·K24.8 BTU/hr·ft·°F
35 W/m·K20.2 BTU/hr·ft·°F

Specific Heat Capacity

475 J/kg·K0.11 BTU/lb·°F
465 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

12.3 µm/m·K6.8 µin/in·°F
12.2 µm/m·K6.8 µin/in·°F

Latent Heat of Fusion

250 J/g107 BTU/lb
270 J/g116 BTU/lb

Min Service Temperature

-30°C-22 °F
-70°C-94 °F

Same in both: Max Service Temperature (continuous) 400°C752 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.6 V
—

Corrosion Resistance

13 / 100
12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

35 / 100
55 / 100

Formability (cold)

25 / 100
55 / 100

Castability

40 / 100
—

Brazeability / Solderability

45 / 100
60 / 100

Same in both: Machinability 50 / 100 · Machinability Rating (AISI 1212 = 100 %) 55% · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

29 MJ/kg12,468 BTU/lb
32 MJ/kg13,758 BTU/lb

Embodied Carbon (primary production)

2.3 kg CO₂/kg
2.4 kg CO₂/kg

Embodied Water

60 L/kg7.2 gal/lb
45 L/kg5.4 gal/lb

Same in both: Typical Recycled Content 30%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

106 kN·m/kg
88 kN·m/kg

Specific Stiffness (E / density)

26.1 MN·m/kg
26 MN·m/kg

Modulus of Resilience

660 kJ/m³
430 kJ/m³

Thermal Diffusivity

11.5 mm²/s
9.6 mm²/s

Thermal Shock Resistance Index

14
10

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale41454815

Manufacturing and finishing

Capability41454815
Default conditionHRHR
Relative cost$$ Standard$$ Standard
Min. machined wall0.8 mm0.8 mm
Best machined surfaceRa 1.6 µmRa 1.6 µm

Both are offered for CNC machining and Sheet metal. Both take the same 38 finishes: AlCrN, AlTiN, Black Oxide, CVD Al2O3, CVD TiCN, CVD TiN, Cerakote, Chrome Plating, Copper Plating, CrN, DLC, E-Coating and 26 more.

4145 vs 4815 — frequently asked

Is 4145 stronger than 4815?

Yes. 4145 has a typical yield strength of 520 MPa (75.4 ksi) against 420 MPa (60.9 ksi) for 4815 — about 24% more. Tensile strength is 830 MPa (120 ksi) vs 690 MPa (100 ksi).

Which is cheaper, 4145 or 4815?

Both sit in the same relative cost tier ($$, standard); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, 4145 or 4815?

4815. Its weldability rates good (55/100) against fair (35/100) for 4145.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4145 and 4815 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.