FabDigitFabDigit

Steel 4145 Annealed vs 4145-CR

Steel · 4145 temper comparison

4145 Annealed and 4145-CR are two conditions of the same steel grade, 4145: Annealed versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. 4145-CR is the stronger of the two: yield strength 700 MPa (102 ksi) against 435 MPa (63.1 ksi) for 4145 Annealed, about 61% more; tensile strength follows at 850 MPa (123 ksi) vs 725 MPa (105 ksi). In exchange, 4145 Annealed is the more ductile: elongation 22% versus 10% for 4145-CR, and 4145-CR is harder (250 HB vs 207 HB). 4145 Annealed runs hotter in service (400°C vs 350°C continuous).

4145 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

4145-CRChoose it when strength drives the design.

4145 Annealed vs 4145-CR: properties

4145 Annealed4145-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

725 MPa105 ksi
850 MPa123 ksi

Yield Strength (0.2% offset)

435 MPa63.1 ksi
700 MPa102 ksi

Elongation at Break

22%
10%

Reduction in Area

52%
35%

Compressive Strength

540 MPa78.3 ksi
720 MPa104 ksi

Shear Strength

500 MPa72.5 ksi
515 MPa74.7 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
385 MPa55.8 ksi

Fracture Toughness (K_IC)

95 MPa·√m86.5 ksi·√in
88 MPa·√m80.1 ksi·√in

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

207 HB
250 HB

Hardness, Rockwell B

94 HRB
100 HRB

Hardness, Rockwell C

22 HRC
24 HRC

Hardness, Vickers

247 HV
263 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,416°C2,581 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
350°C662 °F

Same in both: Thermal Conductivity 43 W/m·K24.8 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 13 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
48 / 100

Machinability Rating (AISI 1212 = 100 %)

58%
52%

Weldability

35 / 100
30 / 100

Formability (cold)

40 / 100
18 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 45 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 29 MJ/kg12,468 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4145

4145 Annealed vs 4145-CR — frequently asked

Is 4145-CR stronger than 4145 Annealed?

Yes. 4145-CR has a typical yield strength of 700 MPa (102 ksi) against 435 MPa (63.1 ksi) for 4145 Annealed — about 61% more. Tensile strength is 850 MPa (123 ksi) vs 725 MPa (105 ksi).

Which condition does FabDigit quote by default, Annealed or CR?

HR is the default 4145 condition in the FabDigit quote flow (neither Annealed nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4145 Annealed or 4145-CR?

4145 Annealed. Its machinability rates good (55/100) against fair (48/100) for 4145-CR; for welding the order is 4145 Annealed first (fair, 35/100) then 4145-CR (poor, 30/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4145 Annealed and 4145-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.