FabDigitFabDigit

Steel 4142-CD vs 4142-HR

Steel · 4142 temper comparison

4142-CD and 4142-HR are two conditions of the same steel grade, 4142: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 4142-CD is the stronger of the two: yield strength 655 MPa (95 ksi) against 450 MPa (65.3 ksi) for 4142-HR, about 46% more. In exchange, 4142-HR is the more ductile: elongation 20% versus 15% for 4142-CD, and 4142-CD is harder (19 HRC vs 17 HRC). 4142-HR runs hotter in service (400°C vs 300°C continuous).

4142-CDChoose it when strength drives the design.

4142-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

4142-CD vs 4142-HR: properties

4142-CD4142-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

760 MPa110 ksi
730 MPa106 ksi

Yield Strength (0.2% offset)

655 MPa95 ksi
450 MPa65.3 ksi

Elongation at Break

15%
20%

Reduction in Area

40%
45%

Compressive Strength

665 MPa96.5 ksi
455 MPa66 ksi

Shear Strength

460 MPa66.7 ksi
440 MPa63.8 ksi

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
330 MPa47.9 ksi

Fracture Toughness (K_IC)

78 MPa·√m71 ksi·√in
80 MPa·√m72.8 ksi·√in

Charpy V-Notch Impact (RT)

24 J17.7 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

223 HB
217 HB

Hardness, Rockwell B

97 HRB
96 HRB

Hardness, Rockwell C

19 HRC
17 HRC

Hardness, Vickers

235 HV
228 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,416°C2,581 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
400°C752 °F

Same in both: Thermal Conductivity 42.6 W/m·K24.6 BTU/hr·ft·°F · Specific Heat Capacity 473 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
54 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
58%

Formability (cold)

32 / 100
42 / 100

Same in both: Weldability 40 / 100 · Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 29 MJ/kg12,468 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4142

4142-CD vs 4142-HR — frequently asked

Is 4142-CD stronger than 4142-HR?

Yes. 4142-CD has a typical yield strength of 655 MPa (95 ksi) against 450 MPa (65.3 ksi) for 4142-HR — about 46% more. Tensile strength is 760 MPa (110 ksi) vs 730 MPa (106 ksi).

Which condition does FabDigit quote by default, CD or HR?

HR is the default 4142 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4142-CD or 4142-HR?

4142-CD. Its machinability rates good (62/100) against fair (54/100) for 4142-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4142-CD and 4142-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.