40NCD3 +C and 40NCD3-IH are two conditions of the same steel grade, 40NCD3: +C (cold drawn) versus IH (induction hardened). The chemistry is identical, so every difference below comes from the condition. 40NCD3-IH is the stronger of the two: yield strength 800 MPa (116 ksi) against 620 MPa (89.9 ksi) for 40NCD3 +C, about 29% more; tensile strength follows at 1,000 MPa (145 ksi) vs 800 MPa (116 ksi). 40NCD3-IH is harder — 555 HB against 240 HB for 40NCD3 +C — which matters for wear surfaces and threads. 40NCD3 +C runs hotter in service (350°C vs 200°C continuous). On the shop floor, 40NCD3 +C machines more easily (good vs poor), 40NCD3 +C welds better (fair vs not recommended), and 40NCD3 +C forms better (poor vs not recommended).

40NCD3 +CChoose it when the part sees heat, or when the part is machined in volume.

40NCD3-IHChoose it when strength drives the design, or when surface hardness matters.

40NCD3 +C vs 40NCD3-IH: properties

40NCD3 +C40NCD3-IH

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

206 GPa29.9 Msi
210 GPa30.5 Msi

Tensile Strength (Ultimate)

800 MPa116 ksi
1,000 MPa145 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
800 MPa116 ksi

Elongation at Break

12%
13%

Reduction in Area

38%
45%

Compressive Strength

640 MPa92.8 ksi
850 MPa123 ksi

Shear Strength

480 MPa69.6 ksi
620 MPa89.9 ksi

Fatigue Strength (Endurance Limit)

370 MPa53.7 ksi
600 MPa87 ksi

Fracture Toughness (K_IC)

68 MPa·√m61.9 ksi·√in
70 MPa·√m63.7 ksi·√in

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

240 HB
555 HB

Hardness, Rockwell C

22 HRC
55 HRC

Hardness, Vickers

250 HV
600 HV

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

44 W/m·K25.4 BTU/hr·ft·°F
43 W/m·K24.8 BTU/hr·ft·°F

Max Service Temperature (continuous)

350°C662 °F
200°C392 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.8 % IACS
7.5 % IACS

Electrical Resistivity

2.2×10⁻⁷ Ω·m8.66 µΩ·in
2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
15 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
15%

Weldability

35 / 100
10 / 100

Formability (cold)

30 / 100
5 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale40NCD3

40NCD3 +C vs 40NCD3-IH — frequently asked

Is 40NCD3-IH stronger than 40NCD3 +C?

Yes. 40NCD3-IH has a typical yield strength of 800 MPa (116 ksi) against 620 MPa (89.9 ksi) for 40NCD3 +C — about 29% more. Tensile strength is 1,000 MPa (145 ksi) vs 800 MPa (116 ksi).

Which condition does FabDigit quote by default, +C or IH?

QT28-32 is the default 40NCD3 condition in the FabDigit quote flow (neither +C nor IH). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 40NCD3 +C or 40NCD3-IH?

40NCD3 +C. Its machinability rates good (62/100) against poor (15/100) for 40NCD3-IH; for welding the order is 40NCD3 +C first (fair, 35/100) then 40NCD3-IH (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 40NCD3 +C and 40NCD3-IH side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.