FabDigitFabDigit

Steel 4037-A vs 4037-CD

Steel · 4037 temper comparison

4037-A and 4037-CD are two conditions of the same steel grade, 4037: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 4037-CD is the stronger of the two: yield strength 585 MPa (84.8 ksi) against 400 MPa (58 ksi) for 4037-A, about 46% more; tensile strength follows at 690 MPa (100 ksi) vs 585 MPa (84.8 ksi). In exchange, 4037-A is the more ductile: elongation 27% versus 15% for 4037-CD, and 4037-CD is harder (200 HB vs 170 HB). On the shop floor, 4037-A welds better (good vs fair).

4037-AChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

4037-CDChoose it when strength drives the design.

4037-A vs 4037-CD: properties

4037-A4037-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

585 MPa84.8 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
585 MPa84.8 ksi

Elongation at Break

27%
15%

Reduction in Area

60%
45%

Shear Strength

380 MPa55.1 ksi
580 MPa84.1 ksi

Fatigue Strength (Endurance Limit)

275 MPa39.9 ksi
330 MPa47.9 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

170 HB
200 HB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 870 MPa126 ksi · Fracture Toughness (K_IC) 75 MPa·√m68.3 ksi·√in · Hardness, Rockwell C 30 HRC · Hardness, Vickers 300 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,416°C2,581 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

60 / 100
50 / 100

Formability (cold)

60 / 100
35 / 100

Same in both: Machinability 65 / 100 · Machinability Rating (AISI 1212 = 100 %) 70% · Brazeability / Solderability 60 / 100 · Polishability 62 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 31 MJ/kg13,328 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4037

4037-A vs 4037-CD — frequently asked

Is 4037-CD stronger than 4037-A?

Yes. 4037-CD has a typical yield strength of 585 MPa (84.8 ksi) against 400 MPa (58 ksi) for 4037-A — about 46% more. Tensile strength is 690 MPa (100 ksi) vs 585 MPa (84.8 ksi).

Which condition does FabDigit quote by default, A or CD?

QT-28-32HRC is the default 4037 condition in the FabDigit quote flow (neither A nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 4037-A or 4037-CD?

4037-A. Its weldability rates good (60/100) against fair (50/100) for 4037-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4037-A and 4037-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.